Owner`s manual
18
INSTALLATION
External Roof-mounted Power Vent System EuropeanHome.com
Figure 7 shows the electrical connections in schematic format with no attention to relative component mounting distances.
Figure 8 is an illustration which is intended to help the installer locate the components in an average installation.
While all parts are subject to local and national code restrictions and limitations some parts have distance limitations and
requirements.
- The E4-SA-SW-80 wall switch has a low voltage, proprietary, built-in 26’ connection cable which may NOT be modied or
extended. The placement of this switch is limited by its cable length and it must be connected to the replace control module.
- The PV-ES-PLS-WHT-02 system switch should be placed next to E4-SA-SW-80 wall switch for convenience.
- The PV-GS-SGV-01 solenoid valve must be connected as close as practical to the gas control valve and after, as the gas ows, the
gas shuto valve.
- The PDS 1 stack probe may be extended up to 25 feet by using ¼” rigid plastic or copper tubing as temperature allows (not
supplied). The PDS 1 must be wired to the PV-GS-CM-ADC 100 with 3-conductor, shielded, 24 AWG cable; maximum length 300
feet.
9
3916067 01.13
ADC 100
To Fireplace
ENERVEX
Fig.7
4.2ConnectionDiagram
The connection diagram shown in Fig. 7 below shows typical connections for a single phase fan. If a 3-phase fan is
used, a VFD must be connected between the fan and control.
ENERVEX®
The connection diagram below shows typical connections
(not used)
Junction Box
(included)
Disconnect
(not included)