Owner`s manual
12
INSTALLATION
External Roof-mounted Power Vent System EuropeanHome.com
ENERVEX®
The power venter can be mounted with plumber’s strap or threaded rod with nuts and washers, or it can
be placed on support legs (included).
As Fig. 6 illustrates, the venter can be placed in virtually any position or direction, except with the motor
pointing down. When placing the venter on the support legs (1), the vibration dampers (4) should be used
and secured by nuts (2).
The support legs are attached to the bottom of the venter using the enclosed sheet metal screws (3). In this
conguration, the venter is typically placed on a shelf hung from a wall.
If hanging the venter from the ceiling, threaded rods should be used. Attach the support legs (1) to the
bottom of the fan and secure with the sheet metal screws (3). Do not use the vibration dampers. Instead,
use the holes on the top of the legs for the threaded rods, and secure these with the nuts (5).
Figure 6.
Next, mount the PV-WM-FAS-01 to the PV-WM-146 fan. The PV-WM-FAS-01 should be rmly supported as local conditions allow.
Slotted angle supported by threaded rod with nuts and washers is recommended Ensure that the parts are square, plumb and
level, fasten the collar of the PV-WM-FAS-01 to the PV-WM-146 fan with at least 3 screws spaced 120 degrees apart and seal the
joint.
Attach one end of the Flexible Fresh Air Duct (provided) to the PV-WM-FAS-01 and the other end to the PV-WM-MAS-01 and
secure each end with a worm-drive clamp (provided).