Specifications
3. Mechanical installation
3.1 Transport safety device
Remove the transport safety device from the vane and make sure that the vane can revolve without hindrance.
3.2 Prior to operation
To open the fan: Remove the two nuts
at the front and pull out the lock pin at
the rear of the fan.
Too secure the fan in open position
place the lock pin in the bracket again.
Always mount the fan in vertical
position.
DO NOT MOUNT HORIZONTALLY
3.3 Single fan on steel chimney
Step 1: Prepare fan location
y If a stack cap is already installed, it must be removed. The steel chimney
adapter (SCA) slides right into the chimney, where the long collar engage-
ment ensures safe anchoring. If necessary, the adapter can be secured by
means of long self-tapping stainless steel screws into the side of the collar
through the chimney wall.
If the steel chimney is air cooled, a special adapter for such
chimney must be used.
y Measure the inside diameter of the ue and cut a corresponding hole in the
center of the ber mat. If the ue is so big that the throat in the adapter has
been reduced to t the throat of the fan, the hole in the ber mat should cor-
respond to the throat.
y The aluminum foil on the ber mat must face upward (against fan base).
6
3100153 RSHT009 - 016 2012-11-15