Specifications

9
3000270 05.12
Bolt
Bolt
!
3.7 Wall Mounting of Chimney Fan
When mounting the chimney fan on a wall, the installation
instructions for installation on a steel chimney should be followed.
Use of the adapter SCA can make the installation easier, but is not a
requirement.
To ease installation, detach the fan base by removing the bolts
holding the hinges together. Center the fan base over the outlet and
bolt the base onto the wall with the hinges pointing upwards.
After mounting the base securely, attach the fan motor housing by
reassemblingthefanhinges.Sealwithsiliconeallaroundtheber
mattopreventrainfromenteringtheue.
3.8 Installation of Proven Draft Switch (PDS)
A safety system must be interlocked with the appliance(s). The
safety system could utilize a Proven Draft Switch, a thermal switch
oraowswitch.Thedevicemustbeinterlockedwiththeheating
appliancesoitshutsdownincaseofinsufcientdraft,fanfailureor
power failure. Please refer to the PDS Installation Manual if this
control is used.
For more information on alternative safety systems, please contact
ENERVEX, Inc.
ThegureshowsthelocationoftheprobeforthePDS.Locationis
important to make sure there is enough pressure or draft available
for the switch to work.
A safety device that prevents the heating appliance
operation, in case of a power failure or inadequate
draft situation, must be installed.