dashes. Up to now the data clearance is finished. The transmitters need to be paired again with the Display Unit
and all settings need to re-done.
Voltage Setting
Upon the Default Display, please press UP/DOWN key to select the Channel number that need to set the voltage.
When the desired channel number appears, press at the same time the OK key and the DOWN key and hold them
there for about 3 seconds until the LCD enters into the voltage setting interface as per below photo where the first
number "1" of 120 (maybe 2 of 230) is flashing.
Please use the UP/DOWN key to scroll to the correct number (0-6) and press OK key for the first number. Then
you will see the second number flashing, please scroll to the correct number (0-9) and press OK key for the second
number. Do the same for the last number to exit the voltage setting.
Every Channel can set a different voltage. If the object is single phase, please just set the single voltage. For
3-phase, the voltage set should be the (line-to-line voltage), not (line-to-neutral voltage). And (line-to-line
voltage)=1.732*(line-to-neutral voltage).
Coding Channels View
If more than one Transmitter is paired with the energy Display Unit, the Default Display displays the total data of
all paired transmitters. To view the information of a single transmitter, press the UP/DOWN key upon the Default
Display to tune into different coding channels for different Transmitters. The CLOCK value will accordingly
change to display the channel numbers for all paired transmitters (from CH01-CH15). And the values on the LCD
screen will immediately change accordingly to provide real time information for the tuned channels.
Pressing the DOWN key upon CH01 or pressing the UP key upon CH15 will return the LCD to the Default Display.
Otherwise the LCD will stay in the display for the selected channel.
Upon the display of single channel viewing, press shortly the OK key once, twice and third times will switch the
display to show hourly/Daily/Monthly forecast of money cost and CO2 emission (unit: kgs) based on current power
under consumption for the selected channel.