Battery Handbook

Page|7
ENERGIZERBATTERYMANUFACTURING
VERSION1.2
Section2:PP355PerformanceCharacteristics
ThissectiondescribestheperformanceofthePP355battery.Standarddischargecurves,performance
atavarietyofenvironmentalconditions,pulsecapability, andservicemaintenancedataarepresented.
2.1‐‐PerformanceatStandardConditions
Standard conditions for Energizer Zinc Air Prismatic batteries are defined as 21°C and 50% relative
humidity(RH).Undertheseconditions,thePP355batteryisdesignedtoprovidecontinuousdischarge
capability up to 100 mW.Whilebest performance is obtainedinstandardconditionsandcontinuous
duty cycles, Energizer Zinc Air
Prismatic Batteries perform well over a wide range of environmental
conditions and in intermittent applications as well.Figure 6 contains typical discharge curves for the
PP355understandardconditionsandconstantpowerloadsof25,50,75,and100mW.
Figure6:PP355DischargeCurvesatContinuousConstantPower
0.8
0.9
1.0
1.1
1.2
1.3
1.4
0 500 1000 1500 2000 2500
Voltage(V)
DischargeEnergy(mWh)
100mW
75 mW
50 mW
25mW
Energizer Zinc Air Prismatic batteries significan tly outperform existing Alkaline cylindrical solutions of
equivalent volume.To demonstrate this advantage, Figure 7 shows how PP355 and AAAA Alkaline
batteriesperformonthesamecontinuouspowertests.ThePP355lastslongerthanthealkalineAAAA
even though the volumes of both battery
types are approximately the same at 2.37 cc and 2.2 cc,
respectively.