Battery Handbook

Page|10
ENERGIZERBATTERYMANUFACTURING
VERSION1.2
Figure8:PulseCapabilityofPP355Batteries
0.0001
0.001
0.01
0.1
1
0 200 400 600 800 1000 1200 1400 1600
MaximumPulseDuration(s)
Current(mA)
1.1VCutoff
1.0VCutoff
0.9VCutoff
0.8VCutoff
2.4‐‐ServiceMaintenance
ZincAirbatteriesarestoredwithadhesivebackedtabspriortouse.Thesetabssealtheairholesagainst
oxygen and water ingress.To obtain the full battery performance, the tab should be removed only
immediately prior touse.When the battery issealed by the tab, service loss due
to self discharge is
approximately5%peryear.Figure10illustratestheratesatwhichcapacityislostwiththetabonand
thetabremoved.
Figure10:ServiceMaintenanceofEnergizerZincAirPrismaticBatteries
80%
85%
90%
95%
100%
01234
Rated Capacity (%)
Shelf Life (yr)
unsealed
(tab removed)
sealed
(on tab)