Specifications

INTRODUCTION
The NightFighter Heads-Up Display System is approved
intrinsically-safe and conforms to UL/ANSI 913 for use in
Class I, Div. I, Groups A thru D hazardous locations, tem-
perature rating T1.
Note: The Nightfighter Heads-Up Display System has
b
een tested and found to comply with the limits for a
C
lass B digital device, pursuant to Part 15 of the FCC
R
ules. These limits are designed to provide reasonable
protection against harmful interference in a residential
installation. This equipment generates, uses and can radi-
ate radio frequency and, if not installed in accordance
with instructions, may cause harmful interference to radio
communications. However, there is no guarantee that
interference will not occur in a particular installation. If this
equipment does cause interference to radio or television
reception, which can be determined by turning the equip-
ment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and
the receiver
• Connect the equipment into an outlet on a circuit
different from that to which the receiver is connect-
ed.
• Consult the dealer or an experienced radio/TV tech-
nician for help.
1. Read and follow all NIOSH and other approval limi-
tations.
2. Do not use this carrier and harness assembly as a
vertical raising or lowering device.
3. Do not use the air mask as an underwater device.
4. This system must be supplied with respirable
[Quality Verification Level (Grade) D, see ANSI/CGA
G-7.1-1989] or higher quality air; and a dew point
not to exceed -65°F (24ppm v/v) [Compressed Gas
Association Specification G-7.1 for Quality
Verification Level (Grade) D Gaseous Air].
5. This device may not seal properly with your face if
you have a beard, gr
oss sidebur
ns or similar physi-
cal characteristics (see NFPA-1500 and ANSI
Z88.2). An improper facial seal may allow contami-
nants to leak into the facepiece, reducing or elimi
-
nating respiratory protection. Do not use this
device if such conditions exist. The face-to-face
-
piece seal must be tested before each use. Never
remove the facepiece except in a safe, non-haz-
ardous, non-toxic atmosphere.
6.
Return to a safe atmosphere immediately if discol
-
oration, crazing, blistering, cracking, or other dete-
rioration of the lens material is observed.
7.
Users must wear suitable protective clothing and
warnings must be taken so that the air mask is not
exposed to atmospher
es that may be har
mful.
8. Take into account the following factors which may
affect the duration or the service life.
a. the degree of physical activity of the user;
b.the physical condition of the user;
c. the degree that the user’s breathing rate is
increased by excitement, fear, or other emotional
f
actors;
d
.the degree of training or experience which the
u
ser has had with this or similar equipment;
e. whether or not the cylinder is fully charged;
f. the presence in the compressed air of carbon
dioxide concentrations greater than the .04%
level normally found in atmospheric air;
g.the atmospheric pressure; if used in a pressur-
ized tunnel or caisson at 2 atmospheres (15psi
gauge) the duration will be one-half as long as
when used at 1 atmosphere; at 3 atmospheres
the duration will be one-third as long;
h.the condition of the apparatus.
Failure to follow this warning can result in serious per-
sonal injury or death.
• Do not use a 2216psi Air Cylinder on a 3000psi
operating system. Such a configuration is not
approved by NIOSH.
• Do not Transfill (be a Donor) using a 3000psi URC
Assembly. The 3000psi URC Assembly has a check
valve that does not allow cylinders to Transfill (be a
Donor).
• Using the 3000psi URC Assembly to fill cylinders,
the cylinder can only be filled to 2216psig. If the
pressure exceeds 2216psig a relief valve in the
URC Assembly will vent at approximately 2525psig
or as low as 2400psig. A 3000psig cylinder can only
be filled to 3000psig by using a secondary air
source; the 3000psi URC Assembly can not be
used for filling a 3000psig cylinder.
• Do not install a Quick-Fill System and 3000psi URC
assembly on the same air mask. Combining these
assemblies on the same air mask will not allow the
r
elief valve in the 3000psi URC Assembly to open
as designed.
Failure to follow the above war
nings can result in seri-
ous personal injury or death.
BEFORE USE
Thoroughly inspect this air mask on receipt and before
use. This air mask is to be used only by trained and quali-
fied personnel. Read and understand these instructions
befor
e attempting to use this equipment. If you have any
questions, call toll free 1-800-MSA-2222.
4
TAL 606 (L) Rev. 16 - 10023638
WARNING
WARNING