Specifications

CLEANING AND DISINFECTING
CLEANING AND DISINFECTING
Depending on the cleaning policy adopted, either a desig-
nated person or the user should clean each device after
each use. ANSI standards suggest that users should be
trained in the cleaning procedure. Confidence Plus
C
leaning Solution (P/N 10009971) from MSA is recom-
m
ended. It cleans and disinfects in one operation. It
r
etains its germicidal efficiency in hard water to inhibit the
growth of bacteria. It will not deteriorate rubber, plastic,
glass, or metal parts. Refer to label for user instructions.
DO NOT use any cleaning substances that can or
might attack any part of the apparatus.
Alcohol should not be used as a germicide because it
may deteriorate rubber parts.
If not rinsed thoroughly, cleaning agent residue may
irritate the wearer’s skin.
1. Preparing Solution
a. Follow the instructions with the Confidence Plus
Cleaning Solution.
b.If the Confidence Plus Cleaning Solution is not
used, wash in a mild cleaning solution, rinse thor-
oughly, and submerge in a germicide solution for
the manufacturer’s recommended time.
2. Clean and Disinfect the Facepiece
a. Remove the mask mounted regulator from the face-
piece.
b.Unthread the thumb screw of NightFighter Heads-
Up Display System receiver and slide the receiver
from facepiece bracket.
c. Thoroughly wash the facepiece (and nosecup) in the
cleaning solution. A soft brush or sponge can be
used to clean the soiled facepiece.
d.Rinse the facepiece and components in clean,
warm (110°F) water (preferably running and
drained).
e. Clean the pressure-demand exhalation valve by
pressing in on the stem with a blunt object and
flushing with clean water.
f. Allow the facepiece to air dry. Do not dry the parts
by placing them near a heater or in direct sunlight.
The rubber will deteriorate.
g
. Operate the exhalation valve by hand to be sure it
w
orks properly.
Note: Do not force-dry the parts by placing them in a
heater or in direct sunlight. The rubber will deteriorate.
When the facepiece is thoroughly dry, store the facepiece
in the plastic bag that it was shipped in.
3. In general, only the facepiece requires cleaning and
disinfecting after each use. If the apparatus is soiled
(i.e. heavy smoke residue or dirt accumulation) use a
sponge damp with mild soap solution or use a
soft/medium bristle brush to remove deposits that
may interfere with normal operation of:
a. Harness (straps and buckles)
b.Cylinder carrier (band and latch assembly)
c. Cylinder (handwheel, gauge, outlet connection)
d.Audi-Larm Alarm with URC Assembly (bell or cou-
pling nut connection)
e. NightFighter Heads-Up Display System/Pressure
Gauge/ICM Unit Gauge
f. MMR remote gauge lens
g. First stage regulator
h. MMR second stage regulator. Cover outlet of the
MMR second stage regulator to prevent water, dirt,
or debris from entering.
4. Inspect the entire apparatus as you re-assemble it.
Follow the Inspection Instructions.
5. Re-attach NightFighter Heads-Up Display System
Receiver
a. Slide receiver onto facepiece bracket.
b.Finger-tighten thumb screw.
6. Thoroughly dry the facepiece and regulator after
cleaning and disinfecting. The facepiece can trap
water, which could enter the regulator.
29
T
AL 606 (L) Rev. 16 - 10023638
CAUTION
CAUTION
C
AUTION