Specifications

URC ASSEMBLY OPERATION
URC ASSEMBLY OPERATION
All NFPA 1981-2002 approved SCBA are equipped with a
URC Assembly (Universal Rescue Connection) fitting. The
URC Assembly is a male quick-fill inlet for use by Rapid
Intervention Crews for emergency filling operations. The
s
ystem also includes an automatically resetting pressure
r
elief valve. The SCBA can also be equipped with a shoul-
d
er mounted quick-fill system, unless using a 3000psi
URC Assembly, the 3000psi URC Assembly can not be
used with Quick-Fill System.
• The URC Assembly is not to be used as a "Buddy
Breather" such that two (2) users are sharing the
air supplied by one (1) approved SCBA cylinder
simultaneously; doing so will void NIOSH approval.
Failure to follow the above warnings can result in
serious personal injury or death.
• The URC Assembly must be used by trained Rapid
Intervention Crews only using procedures devel-
oped for rapid intervention.
Failure to follow the above warnings can result in seri-
ous personal injury or death.
Note:
The URC Assembly may be used for transfill opera-
tions as described in this manual. Standard operating pro-
cedures should be developed for use of the URC
Assembly or Quick Fill System.
Do not install a Quick-Fill System and 3000psi URC
assembly on the same air mask. Combining these
assemblies on the same air mask will not allow the
relief valve in the 3000psi URC Assembly to open as
designed. Failure to follow this warning can result in
serious personal injury or death.
The URC Assembly must be used only by qualified,
trained personnel who have carefully read and understood
these instructions, cautions, and war
nings. NIOSH
approvals of SCBA from MSA are maintained while trans-
filling air ONLY if appropriate Quick-Fill hose assemblies
from MSA ar
e used. URC Assembly or Quick-Fill hose
assemblies and fittings are rated for a maximum working
pr
essure of 4500psig.
NIOSH approval is maintained only when using the follow-
ing Hose Assemblies:
485331, 802687, 802688, 802689, 802690, and 48332, for
filling cylinders in IDLH atmospheres.
• Do not Transfill (be a Donor) using a 3000psi URC
Assembly. The 3000psi URC Assembly has a check
valve that does not allow cylinders to Transfill (be a
donor). Failure to follow this warning can result in
s
erious personal injury or death.
•
Using the 3000psi URC Assembly to fill cylinders,
t
he cylinder can only be filled to 2216psig. If the
pressure exceeds 2216psig a relief valve in the
URC Assembly will vent at approximately 2525psig
or as low as 2400psig. A 3000psig cylinder can only
be filled to 3000psig by using a secondary air
source; the 3000psi URC Assembly can not be
used for filling a 3000psig cylinder.
• Do not lubricate the URC Assembly fittings. Do not
permit oil, grease, or other contaminants to come
in contact with the Quick-Fill fittings. The Quick-Fill
hose assemblies and fittings are designed to be
used with Quality Verification Level (Grade) D or
better air as defined by ANSI/CGA G-7.1.TRANS-
FILLING AIR FROM A SECONDARY AIR SOURCE.
Failure to follow the above warnings can result in seri-
ous personal injury or death.
For Filling Operations using the URC Assembly, do not
use any transfilling hose assembly or fittings other
than those supplied by MSA specifically for the URC
Assembly or Quick-Fill System. Use of any other
transfilling hose assembly, fitting, or cylinder can
result in serious personal injury or death, and will void
NIOSH approval.
A secondary air source stores compressed breathing air
until needed to refill SCBA air cylinders. Secondary air
source pressure must be greater than air mask cylinder
pr
essure. Examples of air sour
ces include: cascade air
cylinder refilling systems; high pressure compressor sys-
tems with a fixed reservoir; and an SCBA air cylinder
which is not installed on an SCBA.
Do not connect a High Pressure SCBA to a secondary
air source with a pressure greater than 4500psig. The
high pr
essure air mask is rated for a maximum work
-
ing pressure of 4500psig. Failure to follow the above
warnings can result in serious personal injury or
death.
25
T
AL 606 (L) Rev. 16 - 10023638
WARNING
W
ARNING
WARNING
WARNING
WARNING