eZV2000P USER GUIDE
The engine exhaust from this product contains chemicals known to cause cancer, birth defects or other reproductive harm. ©2017 Energizer. Energizer and certain graphic designs are trademarks of Energizer Brands, LLC and related subsidiaries and are used under license by Midland Power, Inc. All other brand names are trademarks of their respective owners. Neither Midland Power, Inc. nor Energizer Brands, LLC is affiliated with the respective owners of their trademarks.
Thanks for choosing the EZV Series! You're excited to power up, so we'll keep this brief.
THIS PRODUCT MEETS ALL CERTIFICATION REQUIREMENTS FROM: 263521
WE’VE GOT YOU COVERED! Contact us by phone at 1-877-528-3772, email us at support@energizergenerators.com, or visit us online at www.energizergenerators.com SAVE THESE INSTRUCTIONS This user guide contains important instructions for your product, that should be followed during installation and maintenance of the generator. This user guide covers the safety, operation and maintenance procedures for the EZV2000P.
WARRANTY INFORMATION YOU CAN REGISTER EASILY USING OUR ONLINE FORM: www.energizergenerators.com See ‘Limited Warranty’ for more information. Product registration will allow you to request warranty support in the future. Product registration is required for all product support and warranty coverage. Warranty support, operation assistance and product support is provided by Midland Power Inc., a licensed manufacturer of Energizer Generators. Please contact us directly for any warranty service questions.
TABLE OF CONTENTS 1. Safety Operator Safety AC Safety Maintenance Safety Running Generators in Parallel Other Safety Tips 2. Learn About Your Generator Component Identification Control Panel Control Functions Make Sure You Have Everything 3. Pre-Operation Check 4. Starting the Engine Starting Your Generator 5. Generator Use Output, Overload, and Oil Alert Indicator DC Applications AC Applications AC Parallel Operation 1 1 2 2 3 3 4 4 5 6 7 8 12 13 15 15 16 17 18 6.
1. SAFETY DANGER! USING A GENERATOR INDOORS CAN KILL YOU IN MINUTES. THE ENGINE EXHAUST FROM THIS PRODUCT CONTAINS CHEMICALS KNOWN TO CAUSE CANCER, BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM. 1.1 OPERATOR SAFETY WARNING! Always perform an oil, fuel and air filter check before starting the engine. Properly clean and maintain the equipment. Operate the generator according to instructions for safe and dependable service. Before operating the generator, read the user guide carefully.
Do not touch the spark plug while the engine is operating or shortly after the engine has been shut down. 1.2 AC SAFETY WARNING! Before connecting the generator to an electrical device or power cord: Make sure that everything is in proper working order. Faulty devices or power cords can lead to an electrical shock. Turn off the generator immediately if the device begins to operate abnormally. Then disconnect the device and investigate the problem.
maintenance. Always wear safety glasses when cleaning the generator set with air. Do not clean the generator set with a pressure washer because it can cause damage to the generator set. When working with batteries, ventilate the area, use safety glasses, do not smoke. Always disconnect the negative first and reconnect it last. Use rubber gloves when coming into contact with engine oil. Always stop the generator set before removing the oil filler cap.
2. LEARN ABOUT YOUR GENERATOR This section will show you how to identify key parts of your generator. Going over the terminology below will make sure we’re on the same page. 2.
2.
2.3 CONTROL FUNCTIONS EcoMode (Economy Control Switch) Turn EcoMode ON to minimize fuel consumption. In this mode the engine will dynamically meet the demand of the electrical load and will automatically go into an idle state if all loads are disconnected. Before connecting or removing a high load device to the generator, turn EcoMode OFF until that device has reached running power. When EcoMode is OFF, the engine runs at full speed.
AC Circuit Breakers While the generator is running, the breakers should be in the ON position. If the current has exceeded its limits the breaker will automatically pop out to the OFF position. Reduce the electrical load on the generator and push the button back to the ON position. DC Circuit Breakers The DC circuit breaker automatically shuts off when the charging circuit is overloaded. If the current has exceeded its limits the breaker will automatically pop out to the OFF position.
3. PRE-OPERATION CHECK Set the generator on a level surface and the power switch to OFF. 3.1 PREPARE THE AIR CLEANER Clean and oil the air filter before your first use. Check the maintenance schedule for a complete cleaning guide. 1 2 Air Filter 1. Unscrew and remove the engine access panel. 2. Unscrew the air filter cover and remove the filter. 3. Clean the air filter with soap and water or solvent and squeeze dry. 4. Soak in clean engine oil. 5. Squeeze out all excess oil and reinstall.
3.2 CHECK THE OIL LEVEL 1. Place the generator on a level surface. 2. Effective Engine Oilsrequire some force Unscrew and removeViscosity the engineRange access of panel. This may to loosen the snapfits.Viscosity Range of Engine Oils Effective 3. Unscrew the oil cap and clean the dipstick. 15W-50 4. Reinsert the oil cap without screwing it back in. Remove the cap and 15W-50 examine the oil level on the dipstick. 10W-40 5.
Effective Viscosity Range of Engine Oils 15W-50 10W-40 10W-30 5W-30 -30 -20 -20 -10 0 20 0 10 40 20 60 30 80 40 100 50 °C 120 °F NOTE Do not tilt the generator when adding engine oil. This could result in overfilling and damage to the engine. Use high quality 4-stroke engine oil, certified to meet or exceed API standard SG, SF, SAE ratings with strong detergents. Using nondetergent or 2-stroke oil could shorten the engine’s working life. Do not mix different engine oils.
3.3 CHECK THE FUEL LEVEL NOTE Use of gasoline with an ethanol content greater than 10% can damage the engine and the fuel system and will void the manufacturer’s warranty. Only use unleaded gasoline (Pump Octane 91 or higher). Never use stale or contaminated gasoline, or an oil/gasoline mixture. Avoid getting dirt or water into the fuel tank. Do not use a mixture of gasoline containing methanol. This will cause serious damage to the engine. Fuel Cap Upper Limit Mark (Red) OPEN Fuel Capacity: 3.4L (0.
USING A GENERATOR INDOORS WILL KILL YOU IN MINUTES. GENERATOR EXHAUST CONTAINS HIGH LEVELS OF CARBON MONOXIDE (CO), A POISONOUS GAS YOU CANNOT SEE OR SMELL. IF YOU CAN SMELL THE GENERATOR EXHAUST YOU ARE BREATHING CO. EVEN IF YOU CANNOT SMELL THE EXHAUST, YOU COULD BE BREATHING CO. NEVER USE A GENERATOR INSIDE A HOME, GARAGE, CRAWLSPACE, OR OTHER PARTLY ENCLOSED AREA, DEADLY LEVELS OF CARBON MONOXIDE CAN BUILD UP IN THESE AREAS. USING A FAN OR OPENING WINDOWS AND DOORS WILL NOT SUPPLY ENOUGH FRESH AIR.
4.1 STARTING YOUR GENERATOR WARNING! BEFORE USING THE GENERATOR, A GROUND WIRE MUST BE CONNECTED TO THE GROUND TERMINAL. THE GROUND TERMINAL IS LOCATED ON THE FRONT PANEL. BEFORE USING THE GROUND TERMINAL CONSULT A QUALIFIED ELECTRICIAN. NOTE Before starting the engine disconnect all devices from the outlets on the front panel. Return the starter grip slowly by hand, do not let it snap back.
Carburetor Modification for High Altitude Operation At high altitudes, the standard carburetor air-fuel mixture will be too rich. Fuel consumption will increase and performance will decrease. A very rich mixture will also foul the spark plug and cause hard starting. If using the generator at high altitudes, change the main-nozzle or adjust the idling-screw of the carburetor.
5. GENERATOR USE WARNING! Be sure to ground the generator when the connected electrical appliance is grounded. Do not connect to the building’s electrical system. Doing so may result in electrical shocks and fire. To prolong engine life, do not exceed the rated running wattage. Do not connect an extension to the exhaust pipe. When an extension cable is required, be sure to use a tough rubber sheathed flexible cable (according to IEC245 or equivalent standards).
5.2 DC APPLICATIONS The DC receptacle may be used for charging 12V batteries only. In DC operation, turn EcoMode OFF. NOTE The DC receptacle can be used while the AC power is in use. If used at the same time, be sure not to exceed the total power for AC and DC. (AC: 1600W, DC: 5A) Motor vehicles require more than their rated wattage when starting. Connecting the charging cable: 1. If connecting to a vehicle battery, disconnect the vehicle battery ground cable from the negative (-) battery terminals. 2.
5.3 AC APPLICATIONS 1 2 3 4 1. Start engine and make sure the output indicator light (READY TO USE) is on. 2. Confirm all electrical appliances are switched off, and connect the appliance plugs to the generator receptacle. 3. Turn on the appliances. 4. Turn EcoMode ON. NOTE Confirm all electrical appliances are in good working condition before connecting them to the generator.
5.4 AC PARALLEL OPERATION WARNING! YOU CAN ONLY CONNECT AN ENERGIZER® EZV2000P OR EZV3200P IN PARALLEL WITH THE APPROVED PARALLEL CABLE. ATTEMPTING TO CONNECT A DIFFERENT BRAND OR MODEL IN PARALLEL WITH YOUR GENERATOR WILL VOID YOUR WARRANTY AND COULD CAUSE BODILY HARM. DO NOT START THE GENERATORS BEFORE CONNECTING THE PARALLEL CABLE. IF THE CABLE IS CONNECTED WHILE ONE GENERATOR IS RUNNING IT WILL BE OVERLOADED AND THE ‘RESET’ BUTTON WILL NEED TO BE PRESSED.
6. STOPPING THE ENGINE OPEN 1 2 3 CLOSED 4 Normal Operation: 1. Switch off the connected electrical appliances, and disconnect from the generator. 2. Turn the power switch to the OFF position. 3. Turn the fuel shutoff to the CLOSED position. 4. Turn the fuel cap vent lever to the OFF position. NOTE Make sure the fuel cap vent lever and engine switch are in the OFF position when stopping, transporting, and storing the generator.
7.1 MAINTENANCE SCHEDULE Maintain the generator according to the maintenance schedule in this section. For commercial use, utilize hours of operation to determine proper maintenance intervals. NOTE Service more frequently when used in dusty areas. These items should be serviced by an authorized service center, unless you have the proper tools and are mechanically proficient. Refer to manual for service procedures.
7.2 EMISSION CONTROL SYSTEM Emission Source Exhaust gas contains carbon monoxide, nitrogen oxides (NOx) and hydrocarbons. It is very important to control the emissions of NOx and hydrocarbons as they are a major contributor to air pollution. Carbon monoxide is a poisonous gas. The emission of fuel vapors is a source of pollution as well.
Replacement parts and accessories The parts making up the emission control system in your product’s engine have been specifically approved and certified by the regulatory agencies. You can trust that the replacement parts supplied by customer service have been manufactured to the same production standard as the original parts. The use of replacement parts or accessories which are not designed by – may negatively affect the engine emission performance.
7.3 CHANGING THE OIL WARNING! USED MOTOR OIL CAN CAUSE SKIN IRRITATIONS IF LEFT IN LONG-TERM CONTACT WITH SKIN. THOROUGHLY WASH OFF USED OIL AS SOON AS POSSIBLE WITH SOAP AND WATER. DO NOT DISPOSE OF USED OIL IN DRAINS OR ON SOIL. LOCAL SERVICE SHOPS PROVIDE ENVIRONMENTALLY-FRIENDLY DISPOSAL METHODS. 1 2 3 4 Oil Transfer Tool Oil Cap & Dipstick Drain the oil rapidly and completely while the engine is still warm. 1. Loosen the two screws of the engine access panel and remove the panel. 2.
7.4 CLEANING THE AIR-FILTER WARNING! USING GASOLINE OR OTHER FLAMMABLE SOLVENTS CAN CAUSE A FIRE OR EXPLOSION. DO NOT OPERATE THIS PRODUCT WITHOUT AN AIR FILTER. A dirty air filter will restrict air flow into the carburetor. Clean and maintain the air filter regularly, especially in dusty areas. NOTE NEVER RUN THE GENERATOR WITHOUT AN AIR FILTER, DOING SO WILL QUICKLY DEGRADE THE ENGINE. 1 2 Air Filter 1. Unscrew and remove the engine access panel. 2. Unscrew and remove the air filter assembly. 3.
7.5 SPARK PLUG SERVICE NOTE DO NOT RINSE SPARK PLUG IN WATER. FOLLOW GUIDELINES AND BE CAREFUL NOT TO OVERTIGHTEN THE SPARK PLUG. Recommended spark plug: BPR6HS Check the spark plug gap and clean the carbon deposits at the bottom of the spark plug. TIGHTEN 1/2 TURN WHEN INSTALLING A NEW SPARK PLUG. TIGHTEN 1/8 TO 1/4 TURN WHEN RE-INSTALLING AN OLD SPARK PLUG. 0.60-0.70mm (0.024-0.028in) 1. Remove the spark plug access panel. 2. Remove the spark plug cap. 3.
+ ' " # 7.
8. TRANSPORTATION & STORAGE Transporting the Generator 1. 2. *! ••* 3. Do not overfill the fuel tank (No residual fuel on the neck of tank). Do not use the generator in the vehicle. The generator should ONLY be used while in a well ventilated area. & •• Avoid exposing the generator to prolonged direct sunlight while in an ••" +(••+ •• # enclosed vehicle. The high temperature inside the vehicle could cause fuel •• '••! , •• 4. to vaporize resulting in a possible explosion.
AA97BB A97BB 6. Change new oil while engine is still warm from operation. 7. Remove the spark plug, and pour a tablespoon of clean engine oil (10~20ml) into the cylinder. Revolve the engine several times by pulling on the recoil start to distribute the oil. Reinstall the spark plug. 8. Pull the starter grip slowly until you feel resistance. At this point, the piston is coming up on its compression stroke and both the intake and exhaust valves are closed.
9. TROUBLESHOOTING If the engine does not start: Is there fuel in the tank? NO Refill the fuel tank. YES Is the fuel switch OPEN? NO Turn the fuel switch to OPEN. YES Is the power switch in RUN? NO Turn the power switch to RUN. YES Is there enough oil in the engine? NO Add the recommended oil. YES Is the spark plug in good condition? NO YES If the engine still does not start, contact an authorized dealer 29 Clean, readjust the gap and dry the spark plug. Replace if necessary.
If appliances do not operate: Is the output indicator light ON? NO Is the overload indicator light ON? NO Contact an authorized dealer YES Check the electrical appliance for any fault NO Contact an authorized dealer YES Stop the engine and then replace or repair the appliance YES Restart the engine DC receptacle without any electricity: Repair or replace the appliance.
10. TECHNICAL SPECIFICATIONS SPECIFICATIONS PARAMETERS ENGINE GENERATOR OTHER SPECIFICATIONS Model Name DJ148F Type 4-stroke, overhead valve, single cylinder, forced-air cooling Engine Displacement 79 cc (4.82 cu-in) Bore* Stroke 48.6mm x 43.0mm (1.91x 1.69 in.) Engine Speed 3200-4500 rpm Compression Ratio 7.6:1 Ignition System Full transistor Start System Recoil starter Fuel Type Unleaded Gasoline Oil Capacity 0.35L (0.
• (• 6 =+ $ . 32 #1& $."'# $ $0&. 0 0& $ 6(&'4 2,02($ 0$3 0&% 0$$ 2" 4 60 5 $ " $#-5".' 0$3 6(,$ 6(&'4 5 ".$ 6(,$ 2" 4 %$(( 5 0& $ 0$3 # 0 .$'. 0 8# 0$$ ,0# 1$.$0 0$$ %$(( 5= 0$$ %$(( 5= 0$$ ! ! -2&04#2(, 5 ".$ 6(&'4 0& $ 0& $ # $'$2.&'($ %$(( 5= 0$$ 6(&'4 0$3 2&0&(($(# - '4$. 60 5 60 5 60 5 0& $ 0& $ 6(,$ 6(,$ AA94BB 11. WIRING DIAGRAM .$22$0# .
12. APPENDIX The standard condition of rated power output: Altitude: 0m Ambient temperature: 25°C Relative humidity: 30% Factor of Environment Correction: Altitude (m) Ambient Temperature°C 25 30 35 40 45 0 1 0.98 0.96 0.93 0.90 500 0.93 0.91 0.89 0.87 0.84 1000 0.87 0.85 0.82 0.80 0.78 2000 0.75 0.73 0.71 0.69 0.66 3000 0.64 0.62 0.60 0.58 0.56 4000 0.54 0.52 0.50 0.48 0.46 NOTE: Relative humidity 60% correction factor C-0.
13. LIMITED WARRANTY Toll Free: 1-877-528-3772 E-mail: support@energizergenerators.com Online: www.energizergenerators.com Energizer® Generator products are distributed by: Midland Power Inc. 376 Magnetic Drive, Toronto, ON M3J 2C4, Canada This product is warranted to be free of defects in material and workmanship for three years from date of purchase. This warranty guarantees that any defective parts will be repaired or replaced at no cost, including diagnosis and replacement parts.
THE FOREGOING LIMITED WARRANTY IS EXCLUSIVE OF AND IN LIEU OF ALL OTHER WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND OF ANY OTHER WARRANTY WHETHER EXPRESS OR IMPLIED. Consumable parts, such as oil or fuel filters, fuel cut off valve, brushes, fuel injection nozzle valve, lubricant, or ignition plug, are not covered under this warranty. All expenses incurred in maintaining and replacing parts for generator shall fall on the purchaser.
Batteries Batteries supplied with any generator product should be considered a bonus item and not covered by warranty. Batteries can be damaged by shock, shorting terminals, heat, acid spillage and a number of other factors that cannot be controlled after they have left our facility. It is the customer’s responsibility to take great care when handling a battery so no spillage of acid will occur and cause corrosion; damage caused by battery acid is not covered under this warranty.
Emission Control System Warranty Parts: This list applies to parts supplied by Midland Power Inc. and does not cover parts supplied by the equipment manufacturer. Please see the original equipment manufacturer’s emissions warranty for non-Midland Power Inc. parts. Consumable parts are covered up to a maximum of 30 days.
Warranty Claim Procedure Warranty service must be performed by one of our authorized service dealers. Do not return your product where purchased. If you feel your generator is malfunctioning due to a defect or misuse, simply contact our customer support center for technical advice, a warranty claim or general information. Warranty service, operation assistance and product support is provided by Midland Power Inc., contact us at the numbers below.
Enjoy! Be sure to check energizergenerators.com for updates regarding your generator.