Brochure
Dealer:
Ph: 1300 851 535
|
Unit 11, 1029 Manly Road Tingalpa, Queensland, Australia 4173
|
Email: sales@enerdrive.com.au
|
www.enerdrive.com.au
EN-PK-FEB-2016
FIXED SOLAR PANEL SPECIFICATIONS FOLDING SOLAR KIT SPECIFICATIONS
Part Number (Type) SP-EN10W SP-EN20W SP-EN40W SP-EN55W SP-EN80W SP-EN120W-S SP-EN150W SP-EN200W SPF-EN120W SPF-EN160W
Max Power Pm(W) 10 20 40 55 80 120 150 200 120 160
Power Tolerance % ±3% ±3% 0% - 3% ±3% -1% ~ +3% -1% ~ +3% ±3% -1% ~ +3% ± 3% -1% ~ +3%
Max Power Voltage Vm(V) 16.6 17.6 35.5 18 17.99 17.7 18.8 37.26 18 18
Max Power Current Im(A) 0.613 1.13 1.13 3.05 4.45 6.78 8.01 5.37 6.67 8.9
Open Circuit Voltage Voc(V)
22.3 22.03 43.1 22.29 22.19 22.5 24.0 43.7 22.5 22
Short Circuit Current Isc(A) 0.786 1.5 1.85 3.73 4.85 7.45 8.62 6.17 6.88 9.36
Max System Voltage (VDC) 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
Dimensions (mm) Fixed 320 x 279 x 30 350 x 541 x 30 567 X 670 X 35 840 x 541 x 35 780 x 660 x 35 1578 x 541 x 35 1482 x 660 x 35 1580 X 800 X 40 N/A
Dimensions (mm) Folded N/A
545(w) x 570(h) x 85(d) 670(w) x 780(h) x 75(d)
Dimensions (mm) Open N/A
1100 (w) x 570(h) x 40(d) 1350(w) x 780(h) x 35(d)
Weight (kg) 1 3 4.6 5 7.9 10.2 12 15.3 11.4 15.5
On an average day, you can expect approximately the following amperage into your battery: SPF-EN120W SPF-EN160W
Average daily sun hours 5.5hrs 5.5hrs
Average daily current to battery
Approx 35 amp
hours
Approx 50+amp
hours
Anticipated run time for a typical 50 Litre portable camp fridge (assuming 50% depth of discharge to your 100 amp hour battery) Up to 3 days 3 days +
Test Conditions 1000W/m2 ,AM1.5,25°C
SOLAR CHARGE CONTROLLER SPECIFICATIONS
Model EN41010 EN41020
Battery voltage 12 Vdc 12 Vdc
Max. PV panel open circuit voltage 26 Vdc 26 Vdc
Maximum charge current 10A 20A
Maximum load current 10A 20A
Maximum load current 20A for 1 minute 40A for 1 minute
Operational Current (no load & no PV) <10mA <15mA
Regulated battery charging voltage
Flooded Battery 14.6 Vdc 14.6 Vdc
Sealed Battery 14.2 Vdc 14.2 Vdc
Voltage across terminal (PV to Battery) <0.15 Vdc <0.15 Vdc
Voltage across terminal (Battery to Load) <0.10 Vdc <0.10 Vdc
PV Reverse Polarity Protection Yes Yes
Battery Overcharge Protection
Flooded Battery 14.6 Vdc 14.6 Vdc
Sealed Battery 14.2 Vdc 14.2 Vdc
Load Over Discharge Protection <11.5 Vdc <11.5 Vdc
Load Reconnected Voltage 12.6 Vdc 12.6 Vdc
Battery Chargers Stages 2 Stage, Bulk, Float 2 Stage, Bulk, Float
Recommended Wire Size #12 AWG #10 AWG
Operating temperature - 40º C to 60º C - 40º C to 60º C
SOLAR CHARGE CONTROLLER SPECIFICATIONS (cont.)
Model EN41010 EN41020
Dimensions (mm) (L x W x H) 105 x 105 x 34
Weight 0.3
All Enerdrive products mentioned in this
brochure are backed by our locally serviced 2
year warranty with the addition of our 3 year
pro-rata warranty.
Some Basic Tips
X Keep your panel in direct
sunlight as much as possible
X Secure your Folding Solar Kit
from theft around your work or
campsite
X Protect and store your portable
folding kit in the most secure
place you can to prevent
accidental breakage