Installation Guide
This is for Reference only and local Regulations,
wire size & fusing should be taken into account.
Not to be Copied without permission. Enerdrive Pty Ltd
16mm²
16mm²
   12/24v 
Start Battery
Ignition
 Link
1.5mm²
16mm²
16mm²
12v House Battery
(Optional)
  Battery 
  monitor 
  Shunt
Warning!!
 Fuse
50Amp
  Fuse
40Amp
 (Optional) 
Anderson 
   plug
DC to DC Battery Charger
Please NOTE:
Vehicles with a Smart alternator,
the Negative cable must be 
connected to the vehicle Side
of the Battery Sense Module.
A designated Positive (+) & Negative(-) input cables to 
the DC2DC charger MUST be connected to the engine 
start battery terminals. Using the vehicle chassis as an 
earth return is not permitted. 
For late model vehicles fitted with Smart Alternators, the 
Negative (-) cable must be attached to the vehicle side 
of the alternator sense module. 
Failure to follow these instructions will result in spiking 
the DC2DC unit and causing the internal input fuses to 
blow. 
This is not covered under warranty and the fuses are not 
field serviceable.  
EN3DC30 Install guide
     Addendum ver2
Optional under bonnet 
      ignition relay
Fuse Suit 
Relay Coil
Non Regulated
 Fix or Folding
  Solar Panels
  Max 45VOC
      (500w)
85
30
86
87
16mm²
Hi Amp Relay 
Minimum Rating 70Amp
Ignition sense for smart alternator vehicles.
Smart alternator 
 battery sense 
  module
Also required if start battery has a 
secondary charge source 
i.e. Solar, AC Charger 
See Warning
Smart alternator 
Negative connection 