User Manual

6C6P
Splitter
Box
6C6P
Splitter
Box
DC LOADS +
EN3TOR-G2
Set DipSwitch to:
Standard Program
13/12/2018
GREEN
BLUE
BLACK
RED
WHITE
YELLOW
DC LOADS +
COMMON NEG
Lithium Setup - ePRO 3500 24v - 2018-G2
SR- TS-TOR-G2
SR-TS-TOR-G2
Wire to:
RTS Terminal
1A
10A
NOTE:
Long term storage switch.
Only turn this switch OFF once the batteries
are fully charged, the Yellow Latching Relay
is disengaged and all charging sources have
been shut down correctly.
Enerdrive has provided this drawing as a guide only
and installers must ensure the system is installed to the
local requirements for fuse protection and wire sizing.
If you have any questions please call;
Enerdrive on 07 3390 6900
Temp Sensor
5A
Optional Cabinet Fan
Output 4 Turns on when
Temp Sensor >35
°C
EN3TOR-G2
Plug into BTS
GREEN
BLUE
BLACK
RED
WHITE
YELLOW
EPL-ABS
Battery +
Battery -
+
-
Battery +
Battery -
RED
BLUE
WHITE
YELLOW/GREEN
BLACK
+
-
RED
BLUE
WHITE
YELLOW/GREEN
BLACK
EPL-ABS
Voltage
Protection
Circuit
Battery
Connection
Balancer
Link N/A
Voltage
Protection
Circuit
Battery
Connection
Balancer
Link N/A
2
1
2
1
3
3
Min 50mm Cable with a Max length of
1.5m from Battery to Connection Board.
2
Battery cables must be of equal length and size between
Batteries and busbars to keep the batteries balanced.
1.Voltage protection circuit must
be connected prior to connecting
the Battery connection Plug.
2. Never disconnect Battery
connection wires from the battery
while the lead is connected to the
EPL-ABS box.
3. Only connect Balance wire once
Battery Conection wires and plugs
are connected.
WARNING!
EPL-ABS
Inverter +
Inverter -
EPC-TOR
Twin Core to: Trigger 1/COM
Temp Sensor
(From Output 3) EPC-TOR
Temp Sensor
(from Output 1 o 2)
Twin Core to
Trigger 1/COM
Inside Combi
Twin Core
Wire to:
Trigger 1/COM
AC Switch for
Non essental
loads i.e Aircon
AirCon >%
(from Alarm Expander)
Twin Core to
Trigger 2/COM
Optional
Alarm Expander
3500va 24volt 70a
24V