User Manual
DC LOADS +
EN3TOR-G2
Set DipSwitch to:
Standard Program
12/12/2018
GREEN
BLUE
BLACK
RED
WHITE
YELLOW
Inverter +
Inverter -
DC LOADS +
COMMON NEG
Lithium Setup - ePOWER Dual 12v - 2018-G2
SR-TS-TOR-G2
SR-TS-TOR-G2
Wire to:
RTS Terminal
1A
10A
NOTE:
Long term storage switch.
Only turn this switch OFF once the batteries
are fully charged, the Yellow Latching Relay
is disengaged and all charging sources have
been shut down correctly.
Enerdrive has provided this drawing as a guide only
and installers must ensure the system is installed to the
local requirements for fuse protection and wire sizing.
If you have any questions please call;
Enerdrive on 07 3390 6900
Temp Sensor
5A
Optional Cabinet Fan
Output 4 Turns on when
Temp Sensor >35
°C
EN3TOR-G2
Plug into BTS
EN3TOR-G2
Plug into BTS
GREEN
BLUE
BLACK
RED
WHITE
YELLOW
EPL-ABS
Battery +
Battery -
+
-
Battery +
Battery -
RED
BLUE
WHITE
YELLOW/GREEN
BLACK
+
-
RED
BLUE
WHITE
YELLOW/GREEN
BLACK
EPL-ABS
Voltage
Protection
Circuit
Battery
Connection
Balancer
Link N/A
Voltage
Protection
Circuit
Battery
Connection
Balancer
Link N/A
2
1
2
1
3
3
Min 95mm Cable with a Max length of
1.5m from Battery to Connection Board.
2
Battery cables must be of equal length and size between
Batteries and busbars to keep the batteries balanced.
1.Voltage protection circuit must
be connected prior to connecting
the Battery connection Plug.
2. Never disconnect Battery
connection wires from the battery
while the lead is connected to the
EPL-ABS box.
3. Only connect Balance wire once
Battery Conection wires and plugs
are connected.
WARNING!
EPL-ABS