Product Manual

54
TECHNICAL SPECIFICATIONS
55
MORNINGSTAR CORPORATION
11.0
MECHANICAL
Dimensions (mm/inch) H: 260.4 mm / 10.25 inch
W: 127.0 mm / 5.0 inch
D: 71.0 mm / 2.8 inch
Weight (kg/lb) 1.6 kg / 3.5 lb
Power terminals: compression connector lug
largest wire 35 mm
2
/ 2 AWG
smallest wire 2.5 mm
2
/ 14 AWG
Terminal wire slot 8.2 mm / 0.324 in wide
9.4 mm / 0.37 in high
Knockout sizes 1 and 1.25 inch
Torque terminals 5.65 Nm / 50 in-lb
RTS / Sense terminals:
wire sizes 1.0 to 0.25 mm
2
/ 16 to 24 AWG
torque 0.40 Nm / 3.5 in-lb
ENVIRONMENTAL
Ambient temperature –40 to +45ºC
Storage temperature –55 to +85ºC
Humidity 100% (NC)
Enclosure Type 1 (Indoor & vented),
powder coated steel
Specifications subject to change without notice.
Designed in the U.S.A.
Assembled in Taiwan.
MSZMANTS01B MARCH 10
10.0
Appendix 1 — Load & Lighting Control DIP Switch Settings
The Load Control functions that can be adjusted with the DIP switches follow:
C
ontrol Mode/
D
C Load Control (1)
System Voltage (2,3)
LVD/LVD
R
(4,5,6)
Not Used (7)
Lighting Mode (8)
12345678
DIPON
ON
OFF
Figure 2.3 - Step 3 (Load) DIP Switch Functions
As shown in the diagram, all the positions are in the “OFF” position except
switch number 1, which is in the “ON” position.
NOTE: The DIP switches should be changed only when there is no power to the
controller. Turn off disconnect switches and remove power to the controller before
changing a DIP switch. A fault will be indicated if a switch is changed with the
controller powered.
REMARQUE : Les commutateurs DIP ne doivent être changés que si le contrôleur
est hors tension. Mettez les interrupteurs sur arrêt et mettez le contrôleur hors
tension avant de changer un commutateur DIP. Une panne sera indiquée en cas de
changement d’un commutateur quand le contrôleur est sous tension.
CAUTION: The TriStar is shipped with all the switches in the OFF” position. Each
switch position must be confirmed during installation.
A wrong setting could cause damage to the load or other system
components.
PRUDENCE : Le TriStar est expédié avec tous les interrupteurs en position « ARRÊT ».
La position de chaque interrupteur doit être confirmée pendant l’installation. Un
mauvais réglage peut endommager la charge ou d’autres composants du système.
The DIP switch settings described below are for Load and Lighting Control only.
The DIP switches are shipped in the OFF position. With switches 2-8 in
the OFF position, the following functions are present:
Switch Function
1 Must be “ON” for Load Control
2, 3 Auto voltage select