User Manual
Page 35
Enerdrive ePRO Inverter / Charger Owners Manual
Connected AC output load
causes a short circuit.
Make sure that the AC output
load is not defective. Check
if the AC output wiring
and connections are not
creating a short circuit.
Connected AC output load
causes a too large inrush current.
Try to power-up connected
equipment successively, and
not simultaneously.
Otherwise stop using the
connected load, it’s not
suitable to power it with this
inverter.
Mode indicator
LEDs ‘inverter
on’ and ‘charger
on’ are blinking
red three times
per second.
The ePRO Combi has shut down
due to a too high temperature.
Reduce the AC output
load in inverter mode.
Try to reduce the ambient
temperature around the
ePRO Combi. Make sure that
there is a clearance of at least
10cm around the unit.
Do not obstruct the
airow, place no items
on or over the unit.
Keep the ePRO Combi away
from direct sunlight or heat
producing equipment.