3.3 DIP Switch Settings Overview
During step 3 of the installation guide, you can alter the factory settings
of the DIP switches to change the functionality of the ePRO Combi on
a few points. For additional information about the settings, see the
previous chapter (3.2). The following settings can be made :
Setting Description
Factory setting = OFF
Local / External Programming
ON (External) = DIP switches 2 to 7 or 9 are
ignored and the ePRO Combi will always load the
parameter settings as congured in Dashboard.
OFF (Local) = The local DIP switch settings are used. All
other parameters are set to the factory default settings.
Factory setting = OFF
Inverter output frequency
ON = Output frequency is 60Hz
OFF = Output frequency is 50Hz
Factory setting = ON
Low battery protect
ON = Low battery protect is on
OFF = Low battery protect is o (immediate inverter
shutdown when the battery voltage is < 8.0V)