User Manual

Page 15
Enerdrive ePRO Inverter / Charger Owners Manual
Description The default charge program AGM is compatible with typical AGM
type batteries, but can be used for other types of lead-acid batteries
as well. Please make sure that you always check if the ePRO Combi
charge program settings, are compatible with the used battery! The
AGM charge program absorption voltage is 14.3V (28.6V@24V) and
the oat voltage is 13.3V (26.6V@24V). Other selectable charge
programs are Flooded, GEL and Custom. For further charge program
information, please see chapters 3.3 and 5.1.
Congurable by DIP switch (DIP 5 and 6) and Dashboard
Parameter Charge current limit
Value 100%
Description This parameter sets the maximum charge current in percent. This
value can be set from 10% to 100% by Dashboard or the optional
Universal Remote Control. You can set this parameter to a lower value
when the connected battery is too small and cannot handle the
maximum charge current, or when you wish to (temporarily) reduce
the charger current share, in the total amount of current owing
through the AC input of the ePRO Combi.
Congurable by Dashboard and Universal Remote Control