User Manual

Page 13
Enerdrive ePRO Inverter / Charger Owners Manual
Parameter AC Input Current Limit
Value 16.0A or 30.0A (depending on model)
Description Represents the maximum continuous current that the ePRO Combi
will draw from the AC input source. To assure this, the ePRO Combi
will either reduce the charge current automatically, or (when
enabled) will activate the AC Input Power Boost feature which will
supply the additional power demand by running the inverter in
parallel with the AC input source. When the connected load still
draws too much current, the installer can either choose to deactivate
the AC transfer switch, or keep it closed and allow it to exceed the AC
input current limit value. This value can be set from 1.0A to 16.0A or
2.0A to 30.0A (depending on model) by Dashboard or the optional
Universal Remote Control.
Congurable by Dashboard and Universal Remote Control
Parameter AC Input Power Boost
Value O
Description AC Input Power Boost temporarily assists weak AC input sources
when the connected load needs more power than available from
the grid or generator. This is accomplished by running the inverter in
parallel with the AC input source. The inverter can add power up to
it’s nominal output power rating assuming the battery is healthy. This
parameter can be set On or O.
Congurable by DIP switch (DIP 7) and Dashboard
Parameter Ground switch
Value Enabled