Installation Manual

Solar Connection
Using a genuine "red" Anderson plug, connect your unregulated solar panels directly into
Archie. Use of portable folding panels are recommended when Archie will be used in a
portable application. When installed in a vehicle the use of xed panels may be preferred.
Refer to the Specications table for maximum solar panel rating.
Note: Refer to DC2DC manual for information on wiring for vehicles with smart alternators.
INSTALLATION GUIDE
Connecting to Main (Start) Battery
Using the optional Vehicle Charge Cable Kit connect the lug end to your main/start battery.
The supplied 70A midi fuse must be located as close as possible to the main/start battery.
Connect the "blue" Anderson plug on the cable kit to the blue Anderson Vehicle Input plug.
This input is protected by the "DC2DC" circuit breaker on the rear.
If you select to run your own cabling connect a genuine “blue Anderson plug to the end Archie
will be installed. Connect the other end to you main/start battery. A 70A midi fuse located as
close as possible to the main/start battery is required. Refer below cable sizing chart.
DC2DC Connection
Inputs
Require Length & Battery Cable Size
DC2DC set to
50A Output
From Start Battery
2 Meters to 5 Meters (2)
6-16mm² @ 12vdc 16-35mm² @ 12vdc
/ 4-8mm² @ 24vdc
Up to 10 Meters (2) Greater than 10 Meters
Not Recommended
/ 8-16mm² @ 24vdc