User Manual

Section 1 - Quick Start Guide
Cable Conversion Guide
www.enerdrive.com.au Page 4
Step 1. Connect the Positive (Red) and Negative (Black) cables to the battery, ensuring you are using cable
that is of adequate size for the demands of the system, and well crimped and protected termination lugs.
Example;
1000W Inverter - at least Gauge 2 (35mm²)
2000W Inverter - at least Guage 00 (70mm²)
The spring washers must be used on the battery terminal bolts - they apply pressure to the lugs for a secure
connection. There is no need to over-tighten the bolts, simply ensure there is no movement of the cables.
Make sure the main Battery Cable lug is mounted directly onto the Battery terminal with no washers
between them.
Step 2. Your charger/s need to be programmed for Lithium, with a charging voltage of 14.2 - 14.6 Volts and
Float 13.5 - 13.6 Volts.
Do not use a lead-acid charger if you want the best out of your battery. These chargers can damage the
battery if left connected and will void your warranty.
Step 3. Fully charge the battery and it is ready for use.
*Note: The above is a “Quick Start” guide, detailed information follows.