Owner's Manual
LED Indicators and Digital Display:
Common Mode (Default) & BMS Mode:
Charger will enter charging model when connecting to battery & AC input cable. Digital
display on the front panel will show in turn: AC XXX (Current AC input voltage), CPU X.XX
(corresponding so
ftware version number), b**(Current charging profile code).
To change the charging profile, press & hold the Select button for 5 seconds, then press the
Select button to choose the desired profile. Once selected, press & hold the Select key for 5
seconds, and the charging profile selection will be completed.
To start EQ mode, press & hold the Select button for 10 seconds, and display will show EQ mode.
The next charging cycle will go into EQ mode. If you want to quit the EQ mode, hold the Select
button for 10 seconds. When display shows OFF, the charger will quit the EQ mode.
A: The charger enters BMS mode when being connected to lithium-ion battery through Can Bus;
B:
. For safety reason, the charger will flash "bnS" if being reconnected to Lead-acid battery under a
BMS mode;
C: The charger will only charge Lead-acid type battery again if we refresh the charger through USB
port with the desired lead acid battery charging profile via USB drive.
% Capacity Percentage Indicator: Display shows charging percentage. e.g. 10 20 30...100 (%)
Charging Status Indicator and Status Display
B Battery Voltage Indicator. To check battery voltage, disconnect charger AC input and press
“Select” button for 1 second. Display shows battery voltage. e.g. 24.0 (V).
Additional Battery Voltmeter Function
V Charging Voltage Indicator: Display shows charging voltage. e.g. 24.0 (V)
A Charging Current Indicator: Display shows charging voltage. e.g. 36.0 (V)
Page 8 Enerdrive ePOWER Industrial Battery Charger Owner’s Manual (Rev. 1.7)