ePOWER Battery Charger Manual

Program (Power Supply) Type
Parameters below are required for setting:
Supply Voltage 13.3, 13.5, 13.7 Vdc
Maximum available current (see table)
The following table shows the programmable voltage and the maximum current setting.
Model Program Output Voltage Setting Max. Current
EN31220 13.3V/13.5V/13.7V 20A/15A/10A/5A
EN31240 13.3V/13.5V/13.7V 40A/20A/10A/5A
EN31260 13.3V/13.5V/13.7V 60A/40A/20A/5A
EN32430 26.6V/27.0V/27.4V 30A/20A/10A/5A
EN312100 13.3V/13.5V/13.7V 100A/80A/60A/40A
Procedure To Equalise Flooded Battery
DANGER Explosion hazard and risk of battery damage
The battery generates explosive gases during equalisation. Follow all the battery safety precautions
listed in the manual. When using the equalisation mode, the user has to be sure the battery connected
to the channel is a ooded battery type. Equalising a non-ooded battery may overcharge the battery
and may cause the battery to explode.
Page 30 Enerdrive Battery Charger Owners Manual Rev. 5.4