ePOWER Battery Charger Manual

Procedure To Set Or View Charger Setting
Follow the procedure or sequence in Appendix A1 and A2 (see pages 38 to 41 of this manual) to set or
view the charger setting.
GEL, AGM Or Flooded Battery Type:
Parameters below are required for setting:
Battery type (GEL, AGM, Flooded)
Maximum Current setting (see table below)
Charging stage (3-stage , 2-stage)
Battery temperature (low, normal, high temperature) or connect the temp sensor to over-ride
The following table shows the maximum available charging current and its related available Absorption
to Float Mode current.
Model Charging Voltage Maximum Charging Current Termination Charging Current
EN31220 14.2V / 14.3V / 14.4V
* 20A 2A / *4A / 6A
15A 1.5A / 3A / 5A
10A 1A / 2A / 3A
5A 0.5A / 1A / 1.5A
EN31240 14.2V / 14.3V / 14.4V
* 40A * 4A / 6A / 8A
20A 2A / 4A / 6A
10A 1A / 2A / 3A
5A 0.5A / 1A / 1.5A
EN31260 14.2V / 14.3V / 14.4V
* 60A * 6A / 9A / 12A
40A 4A / 6A / 8A
20A 2A / 4A / 6A
5A 0.5A / 1A / 1.5A
EN312100 14.2V / 14.3V / 14.4V
*100A * 3A / 4.5A / 6A
80A 2A / 4A / 6A
60A * 6A / 9A / 12A
40A 0.5A / 1A / 1.5A
Note: * Recommended setting (Factory Default Setting)
Absorption to oat mode current setting (see table below)
EN32430 28.4V / 28.6V / 28.8V
* 30A * 3A / 4.5A / 6A
20A 2A / 4A / 6A
10A 1A / 2A / 3A
5A 4A / 6A / 8A
Page 28 Enerdrive Battery Charger Owners Manual Rev. 5.4