Understanding The Display And Function Keys During Normal Operation
The charger can be used as a constant voltage power supply that will deliver the preset output voltage
(13.3, 13.5, 13.7 V) with the maximum current setting. With this setting, only Bank 1 can be used and the
other banks are disabled (double this number for 24V).
This can only be set at Bank , it has its own charging voltage and current setting. It also requires the user
to set the charger termination current. The charging process will terminate when the charging current
drops to the set termination current. Bulk re-start occures when battery voltage drops below 13.3V DC.
EN312100 can be programmed for Lithium on 2 & 3.
With this setting, only Bank 1 can be used and the other banks are disabled.
NOTE
During normal operation, the display shows the related channel’s battery voltage, charging current and
charging stage (‘bUL’ – Bulk stage, ‘Ab5’ – Absorption stage, ‘FLo’ – Float stage) alternatively. When the
‘MENU’ key is pressed, it displays the other channel’s battery voltage only.
When all channels reach oat stage, the display will show ‘Ful’ indicating all the batteries connected are
fully charged and presently in oat mode.