Smart Charging Feature
Battery Charger Algorithm
EN31220, EN31240, EN31260, EN32430
The Battery Charger will regulate its output based on the loads connected to your battery banks. This
function is important to maintain the life of your battery banks as some battery chargers mistake loads for
discharge and continue to keep the batteries in the bulk or absorption stage for extended periods of time,
which will damage the battery bank. The Battery Charger has two methods of load based regulation to
ensure your battery charger transitions to oat when it should do so.
www.enerdrive.com.au Page 13
Lithium Battery charging algorithm
14.4V
14.2V
14.0V
13.8V
13.6V
13.4V
13.2V
13.0V
12.8V
Battery Current
Bulk Float
Time out 8 hrs max Time out 7 days
Diagram does not illustrate our current set points.
Maint. Float Return to Bulk
Battery Voltage
13.2VDC triggers
Bulk Restart
Note: Actual voltages depend on chosen algorithm.