Datasheet
8.15
8.16
8.17
13.1
13.2
Overcharge Test
Overdischarge Test
Charge by constant Current of 2C and constant voltage
of 5V for 2 hours.
No fire. No explosion.
Short circuit the lead wire (resistance 30mΩ or under)
across" + "and" - "terminals of the Battery after standard
charging.
No explosion, and no fire
No explosion, and no fire
the date of shipment or for 300 cycles (see 8.10), whichever comes earlier.
The warranty set forth above or described in Handling Precautions and Prohibitions for Lithium Ion Rechargeable
Batteries excludes a defect, which is not related to manufacturing of the Battery.
Packing state - Charging capacity of delivered Battery is about 60%
11. Packaging State
Any other matters that the specification does not cover should be conferred between the both parties.
9. Product Liability
The indications of a warning are established by conference with between the both parties.
Product drawing - Refer to appended Drawing. (Page 10)
10. Outline Dimensions
As long as the Battery is treated in accordance with this Product Specification and / or Handling Precautions and
Prohibitions, Supplier warrants that the Battery should be free from any defect for a period of 1 year (20 ℃ or less) from
13. Others
Storage for a long time if Battery or pack is preserved for a long time (3 or 4 months), the Battery or pack is
preserved at the 40+/-20%RH and 23+/-2℃ temperature.
12. Warranty
Items
Short Circuit
The results of the conference must be recorded and the range of the liability or the burden should be cleared.
The Safety should be sure to confer previously with between the both parties.
Lithium-ion Rechargeable Battery
Test methods Judgment criteria
After standard charge .Discharged by constant Current
of 0.2C to 3.0V,and the positive and negative terminal is
connected with a 30Ω wire for 24 hours.
Page 7 of 10