B PL LED-indicator B lights green when the camera is switched on.
C Power supply / 12VDC/24VAC power supply. Power supply unit see „Specications”.
power cord 230VAC power supply via power cord C. Make the connections rst, then switch
the unit on.
D LEVEL Output level adjustment with potentiometer D for DC controlled lenses.
P PHASE Potentiometer P for phase adjustment for mains sychronization.
E LENS Connection E for DC or AI controlled lenses. Connect the cable of lenses
with automatic iris control to the supplied 4 pin DIN plug. (Only for AI lenses
which are designed for operation with 9-12VDC and 50mA max.)
F 1 ... 8 DIP-Switch F to change the settings described under „DIP-Switch settings”.
G VIDEO OUT Video output G (BNC) for connection of external units (e.g. monitor, 75Ohm).
HO, Camera mount 1/4”-20UNC-thread HO/HU for camera mounting, for example on a tripod,
HU ceiling mount or P&T head.
N Dust cover To protect the CCD-sensors the camera module. Always attach dust cover N
when no lens is mounted.
K,L C/CS mount CS mount L for CS mount lenses. Insert the supplied C mount ring K
if C mount lenses are used.
M Locking screw To adjust the ange focus open screw M, turn the at CS mount ring L until the
focus maximum is achieved and fasten the screw again.