Specifications

5.5 Installation and commissioning Instructions
Make sure the power is removed before the installation.
After all connections are finished properly, follow the order for applying power.
a) Plug the network cable into RJ-45 Ethernet Port at the rear panel.
If PoE is the unique power, there will be no need to connect Power terminal.
b) When DC12V or AC24V Local power is necessary, first connect the low voltage (DC12V or AC24V),
then plug the AC adapter to AC outlets to avoid an improper reset from power jitter and a damage
from the surge voltage when no load.
When PoE and Local power are connected, Local power has priority.
5.6 Power Supply Connections
Camera can work with either 24AC or 12VDC, dual voltage power and PoE(IEEE Std. 802.3af).
Primary and secondary grounds are completely isolated to avoid the possible ground-loop problems.
11