Operating instructions
7
3.3 ALARM I/O PIN Configuration
1. RS-485 pin: D+
2. RS-485 pin: D–
3. GND1: Ground Contact
4. ALARM RESET (INPUT): This pin connects to an alarm-clear device for clearing an alarm (
5V
0V(Active)
).
5. GND2: Ground Contact
6. ALARM IN 1 (INPUT): This is an alarm input which can be programmed in the menu system to Normally Open
or Normally Closed (
5V
0V(Active)
).
7. ALARM IN 2 (INPUT): This is an alarm input which can be programmed in the menu system to Normally Open
or Normally Closed (
5V
0V(Active)
).
8. ALARM IN 3 (INPUT): This is an alarm input which can be programmed in the menu system to Normally Open
or Normally Closed (
5V
0V(Active)
).
9. ALARM IN 4 (INPUT): This is an alarm input which can be programmed in the menu system to Normally Open
or Normally Closed (
5V
0V(Active)
).
10. ALARM IN 5 (INPUT): This is an alarm input which can be programmed in the menu system to Normally Open
or Normally Closed (
5V
0V(Active)
).
11. ALARM IN 6 (INPUT): This is an alarm input which can be programmed in the menu system to Normally Open
or Normally Closed (
5V
0V(Active)
).
12. GND3: Ground Contact
13. AUDIO IN Connector: The connector is used to connect the audio output from a camera or other devices.
14. AUDIO OUT Connector: The connector provides the unit’s audio signal to a speaker or stereo.
15. GND4: Ground Contact
16. ALARM OUT 1 (OUTPUT): This is an alarm-output trigger. Connect this to external devices such as buzzers or
lights (
5V
0V(Active)
).
17. ALARM OUT 2 (OUTPUT): This is an alarm-output trigger. Connect this to external devices such as buzzers or
lights (
5V
0V(Active)
).
18. ALARM OUT 3 (OUTPUT): This is an alarm-output trigger. Connect this to external devices such as buzzers or
lights (
5V
0V(Active)
).
19. ALARM OUT 4 (OUTPUT): This is an alarm-output trigger. Connect this to external devices such as buzzers or
lights (
5V
0V(Active)
).
20. ALARM OUT 5 (OUTPUT): This is an alarm-output trigger. Connect this to external devices such as buzzers or
lights (
5V
0V(Active)
).
21. ALARM OUT 6 (OUTPUT): This is an alarm-output trigger. Connect this to external devices such as buzzers or
lights (
5V
0V(Active)
).
22. GND5: Ground Contact
23. DC-OUT: DC-12V 350mA max.
24. GND6: Ground Contact