Installation and Operating Manual Fastrax Dome Video Camera for Ceiling and Wall Mounting EDC-141E, EDC-142E, EDC-143E 1
Contents 1. Introduction .............................................................................................................................................................................................................. 3 1.1 Features ................................................................................................................................................................................................................... 3 2. Installation and Configuration ............
Safety Instructions • Read these safety instructions and the operation manual first before you install and commission the camera. • Keep the manual in a safe place for later reference. • Protect your camera from contamination with water and humidity to prevent it from permanent damage. Never switch the camera on when it gets wet. Have it checked at an authorized service center in this case. • Never operate the camera outside of the specifications as this may prevent the camera functioning.
Figure 1 - Typical System Configuration Figure 2 - Assemble bubble ring ass’y Note: It is recommended to remove camera window for improving picture quality when you assemble bubble ring ass’y.
2. Installation and Configuration 2.1 Package Contents The package contains the following. 1x Fastrax II E (Dome Camera) 1x Bubble Ring 1x Instruction Manual (This Document) 3x Assembly Screws for Attaching Fastrax II E 3x Plastic Anchor 1x 10Pin Connector 2x12Pin Connector CAUTION: Be sure to have caution labels(E version only) on both body and base of the camera. Different version will not support alarm input and output.
2.2 Basic Configuration of Fastrax II Dome Camera System Figure 4- Basic installation diagram The dome camera must be installed by qualified service personnel in accordance with all local and federal electrical and building codes. The system should be installed according to Figures 4 through 9.
2.2.
2.2.
2.2.
2.2.
Figure 9 - Layout of Switches 2.3 Setting Unit for Termination The device which is connected at end of line, whether it is a dome camera or keyboard controller, must be terminated by setting the appropriate DIP switch. Without proper termination, there is potential for control signal errors. Total length of the cable for communication should not exceed 1.2km.
Figure 11 - Termination Diagram 2.4 Setting Address (ID) of Dome Camera To prevent damage, each dome camera must have a unique address (ID). When installing multiple dome cameras using a multiplexer, it is suggested that the dome camera address matches the multiplexer port number. If you wan to set the address more than 999, you should connect the service provider. Example: Port 1 = Dome 1, Port 2 = Dome 2 ... Port 16 = Dome 16.
2.5 Setting Protocol of Dome Camera If a dome camera is to be installed with a Fastrax keyboard controller, select F2 protocol. Consult service personnel if a dome camera is installed with device other than a keyboard controller.
2.6 Connections • Connecting to the RS-485/-422 The dome camera can be controlled remotely by an external device or control system, such as a control keyboard, using RS-485 half-duplex, RS-422 duplex or simplex serial communications signals. Connect Marked Rx+, Rx- to Tx+ and Tx- of the RS-485 control system. If control system is RS-422, connect Rx+ (Tx+), Rx+ (Tx-) and Rx+, Rx- of the dome camera to Tx+, Tx- and Rx+, Rx- of the control device respectively.
3. Program and Operation 3.1 Selecting Dome Camera Before you program or operate a dome camera, you must select the dome camera by pressing the dome camera No. + CAM successively. Example: Pressing 1, 0 and CAM key sequentially will select dome camera 10. The selected dome camera ID will be displayed on the LCD monitor of the keyboard controller. 3.
3.4 Auto Scan (First Item of the Main menu / Shortcut: Scan) The Auto scan supports up to 8 programmed angles at user-programmable speeds. Follow these steps to program Auto Scan: AUTO SCAN SETUP SCAN 01 : AUTOSCAN01 SPEED(MODE) : FAST VECTOR START ANGLE : 127.1, 027.7 X7 END ANGLE : 157.7, 080.7 X13 SCAN DIR. : CCW SWAP : OFF SAVE AND EXIT (ESC TO CANCEL) HOLD DOWN CTRL KEY WHILE SELECT POSITION.
3.5 Preset (Second Item of the Main menu / Shortcut: Prst) If you need to view specific locations routinely, you should program presets. A preset is a programmed video scene with automatic pan, tilt, zoom, focus and iris settings. Once programmed, entering the number and pressing a preset button on your controller automatically calls up the preset. In addition, presets may be assigned to alarm actions or as the „home” position for the dome camera.
3.6 Shortcut of Preset Program Select a view to be stored (direction of the camera, zoom and focus), then press No. (1 to 240), and then press Pgm, Prst subsequently. The current view will be stored to the selected preset number if position is empty. If selected preset number is not empty, „PRESET EXISTING” message will be displayed on the monitor and ask to overwrite. Example: 1, 0, 1 + Pgm + Prst will store current view as preset No. 101.
4. To add a stored preset as a Tour, twist the Zoom handle or press Zoom Key (Programmed preset will scroll). To remove a stored preset from the Tour, press the Home key, blank position mark (===) will be displayed. You can overwrite the programmed position. 5. To place functions other than preset, press Tour, Ptrn, or Scan for Tour, Pattern or Auto Scan respectively and the use zoom handle or key to select No. 6. Repeat Step 2 through 5 for each desired position.
3.9 Alarm (This menu shows on only specific model, Fifth Item of Main menu) ALARM SETUP NO PRIO PRS IN OUT HOLD LATCH 01 1 001 OFF OFF 03 OFF 02 8 001 OFF OUT1 03 OFF 03 1 240 NO OUT1 03 OFF 04 2 001 NC OUT4 03 OFF 05 1 001 OFF OFF 03 OFF 06 8 001 OFF OUT1 03 OFF 07 1 240 NO OUT1 03 OFF 08 2 001 NC OUT4 03 OFF SAVE AND EXIT ( ESC TO CANCEL) NO : Alarm input number PRIO : Lower No. has higher priority, Equal priority alarms will be serviced repeatedly.
Pages can be scrolled through by pushing the Joystick to the left or right on the first or last column of the menu. Pushing the Joystick to left on the „NO” column (01 ~ 08) of the menu to scroll to the previous page. Push the Joystick to right on the „END” column to go to the next page. 1. Press Menu to display the main menu on the monitor. Select the Area Title option by pushing the Joystick up or down and push to right to enter the detail menu. 2.
3.12 Camera (Eighth Item of Main menu) NOTE: The menu features will vary depending on the camera module installed in your dome camera. CAMERA SETUP FOCUS CONTROL WB CONTROL AE CONTROL LINE LOCK CONTROL SHARPNESS : 9 BACK LIGHT : OFF DIGITAL ZOOM : OFF/2x/4x/ MAX NIGHT SHOT CONTROL (optional) SAVE AND EXIT(ESC TO CANCEL) SHARPNESS The higher the value, the more edges in the picture will be enhanced (0~15). BACK LIGHT Objects in front of bright backgrounds will be clearer with BLC ON.
• AE CONTROL AE SETUP MODE : FULL AUTO SLOW SHUTTER : MANUAL IRIS : F2.4 GAIN : 0 DB BRIGHT : 14 SHUTTER : 1/60 SAVE AND EXIT(ESC TO CANCEL) MODE FULL AUTO / MANUAL / SHUTTER PRIO / IRIS PRIO / BRIGHT SLOW SHUTTER AUTO / MANUAL ----- IRIS CLOSE / F22 / F19 / F16 / F14 / F11 / F9.6 / F8.0 / F6.8 / F5.6 / F4.8 / F4.0 / F3.4 / F2.8 / F2.4 / F2.0 / F1.6 / F1.4 GAIN 0 / 2 / 4 / 6 ...... / 28 / -3 DB BRIGHT 0, 2, 3, 4 ..... 29, 30 SHUTTER 1/1 , 1/2 , 1/4(3), 1/8(6). ..
3.13 Dome Setup (Ninth Item of Main menu) CONFIGURATION MENU HOME FUNCTION SETUP OSD DISPLAY VIEW ANGLE SETUP INITIALIZE DATA ORIGIN OFFSET DOME RESET SYSTEM INFORMATION EXIT(ESC TO EXIT) • HOME FUNCTION SETUP After a dome control menu item has been selected, follow the directions below to set the function.
CAMERA TITLE : 8 CHARACTER CAN BE SET VIEW DIRECTION : ON / OFF DOME OSD DISPLAY : ON / OFF AREA DISPLAY : ON / OFF TILT OVER ANGLE : ON / WITH BUBBLE / W/O BUBBLE FILP : ON / OFF • VIEW DIRECTION „ON” sets current direction as N(north) and the coordinate angle to 000. „OFF” hides the directional title. Every 90 degrees of clockwise rotation will change the title to E(East), S(South), W(West). If using the ON/OFF option frequently, it is recommended that you set „North” as a Preset.
• FLIP Allows the dome camera to automatically turn 180 degrees when the camera tilts to its lower position. When camera reaches floor alone moving object, it will stop. Release the Joystick handle instantly and then pull down to run flip fucntion. The speed of following object will be same speed as previous. • INITIALIZE DATA INITIALIZE DATA FACTORY DEFAULT ERASE PROGRAMMED DATA EXIT(ESC TO EXIT) Erase all stored data from the Flash-ROM of the selected dome camera. You will be asked to enter Yes or No.
4. Troubleshooting If problems occur, verify the installation of the camera with the instructions in this manual and with other operating equipment. Isolate the problem to the specific piece of equipment in the system and refer to the equipment manual for further information. Problem No video Poor video quality Dome cameras lose their positions. Camera number does not match the multiplexer number.
Privacy Zones Shutter Limit Vector Scan WDR White balance This function maskes areas of the dome camera's viewing area. These masks prevent operators of the surveillance system from viewing these designated zones. The Privacy Zones move in relation to the dome camera’s pan/tilt position. In addition, the apparent size of the Privacy Zone adjusts automatically as the lens zooms in or out. Up to eight Privacy Zones may be established for a dome camera.
Type EDP No.