Operating Instructions Digital Video Recorder BCR-3004, BCR-3008 und BCR-3016
Contents 1. Safety Instructions / Maintenance........................................................................................................................ 3 2. Product Features................................................................................................................................................. 4 3. Function of Buttons............................................................................................................................................. 5 4.
1. Safety Instructions / Maintenance • Read these safety instructions and the operation manual first before you install and commission the unit. • Keep the manual in a safe place for later reference. • The system may only be commissioned and maintained by personnel authorized to do this and it must only be carried out in accordance with relevant standards and guidelines. • Never cover the ventilation slots to avoid overheating. • Never insert metal objects or any other items into the vents.
2. Product Features • BCR-3004: BCR-3008: BCR-3016: 4 Loop-through Video Inputs / VGA, Composite Outputs 8 Loop-through Video Inputs / VGA, Composite Outputs 16 Loop-through Video Inputs / VGA, Composite Outputs • Alarm Inputs / Outputs • Pentaplex Operation • MPEG-4 Video Compression • Recording Speed: BCR-3004: BCR-3008, BCR-3016: 100 ips. max. 200 ips. max. • Video Resolution 704x576 Pixels max.
3. Function of Buttons 3.
NOTE: This manual covers the 4 channel, 8 channel and 16 channel digital video recorders. For simplicity, the illustrations and descriptions in this manual refer to the 16 channel model. No.
3.
NOTE: You cannot mix NTSC and PAL equipment. For example you cannot use a PAL camera and a NTSC monitor. No.
3.3.3 LAN No. Details No. Details 1 TX+ (Data Transmission) 5 N/C (Normal Close) 2 TX- (Data Transmission) 6 R/X- (Data Transmission) 3 RX+ (Data Transmission) 7 N/C (Normal Close) 4 N/C (Normal Close) 8 N/C (Normal Close) 3.3.4 CAMERA input & LOOP output Camera Input Loop Output 3.3.5 External Device Connection: Connection with PTZ camera, sensor, relay output 4 Channel No. Details No. Details No. Details No.
16 Channel No. Details No. Details No. Details No. Details 1 RS485 D- 2 RS485 D+ 3 AL COMM2 4 AL NC2 5 AL NO2 6 AL COMM1 7 AL NC1 8 AL NO1 9 GND 10 ALARM 16 11 ALARM 15 12 ALARM 14 13 ALARM 13 14 GND 15 ALARM 12 16 ALARM 11 17 ALARM 10 18 ALARM 9 19 GND 20 ALARM 8 21 ALARM 7 22 ALARM 6 23 ALARM 5 24 GND 25 ALARM 4 26 ALARM 3 27 ALARM 2 28 ALARM 1 4. Installation 4.
4.2 Hardware Installation 4.2.1 Rack Mounting 1. Remove the cross head screws (four on each side) located near the front panel on the right and left side of the unit. 2. Secure the rack mount brackets to each side using same cross head screws that were just removed. 3. Install the unit into the 19 inch wide rack (follow the rack manufacturer’s instructions.) 4.2.
4 Channel HDD Cable Connectiom HDD Fix 8 Channel HDD Cable Connectiom 16 Channel HDD Cable Connectiom 12
4.2.3 Camera Rear view of camera Connect cameras to the camera input on rear panel of DVR marked CAMERA IN. 4.2.4 Monitor Connect the video output marked MONITOR to VIDEO-IN of Main Monitor. 4.2.5 Power Cable Connect DC 12V, 6.67A Adaptor to the back side of Power Jack for proper operation of 2HDDs and optical drive. Before turning on, be sure all necessary devices such as Power adaptor, cameras and Monitor are connected properly to DVR! NOTE: This unit is for 12VDC.
4.2.6 SPOT Monitor installation (Call Monitor) Optional: Connect BNC type monitor for SPOT monitor installation (Call Monitor). 4.2.
16 Channel RS-232C: Control DVR through RS-232C port RS-485: Control external device such as PTZ Cameras (Pin No.1 ~ 2 at Terminal Block) RELAY Output: (Pin No.3 ~8 at Terminal Block) SENSOR Input: (Pin No.10 ~ 13 / No. 15 ~ 18 / No. 20 ~ 23 / No. 25 ~ 28 at Terminal Block) GND: Ground (Pin No. 9 / No. 14 / No. 19 / No.
5.
5.1 Current Status 5.1.1 Date/Time Live mode: show current date & time Playback mode: show recorded date & time of the playback image 5.1.2 HDD Live mode: HDD recorded space is marked red on the percentage bar. Available remaining days/time at current record mode is shown. Playback mode: Shows percentage of playback. 5.1.3 Playback Mode In Playback mode, F stands for Forward playback, B for Backward playback. The numbers show playback speed. (Example.) F 16x, B 2x 5.
5.3 Popup Menu There are three types of Popup Menu: 1. „MONITORING” popup menu 2. „PTZ CONTROL” popup menu 3. „PLAYBACK” popup menu The Popup menus are provided for easy navigation and detail configuration. See each sectional explanation for invoking popup menus. 5.3.1 MONITORING Popup Menu The „MONITORING” popup menu is invoked by pressing „Menu” button located in front of the DVR, „Menu” button located on the remote controller and right mouse button while in Live display.
• Previous Page By selecting „PREVIOUS PAGE” option in full screen mode, screen display view will switch screen to lower number channel. (After channel 1, it rotates to channel 16.) In split screen mode, clicking Previous Page menu will switch screen to lower number channel groups. e.g. [ch1/2/3/4] –> [ch13/14/15/16] –> [ch9/10/11/12] –> [ch5/6/7/8] In 16 split display mode, this function is not available.
4) FREEZE (On / Off) Select „FREEZE” from „MONITORING” popup menu. NOTE: By pressing button marked „FRZ” on frontal key pad or remote controllers will freeze the screen and hitting it one more time will release it. Select „ON” that appears on expanded window from „FREEZE” selection to freeze the frame and „Off” to release the screen freeze. In Full screen mode, FRZ icon appears and screen freezes. In split screen mode, FRZ icon appears and all channels freeze.
After selecting „DISPLAY” and a window will appear with „OSD”, „MAIN”, „SPOT” and „VGA” tabs. Select „MAIN” tab and here you can configure sequence interval. 7) PIP: On / Off Picture in Picture (PIP) mode will be enabled by selecting PIP button on the remote controller or in frontal keypad. With mouse operation, PIP will be enabled from „MONITORING” popup menu then selecting „PIP”. From here you have an option to select „ON” or „OFF” to enable and disable PIP.
After selecting „DISPLAY” and a window will appear with „OSD”, „MAIN”, „SPOT” and „VGA” tabs. Select „MAIN” tab and here you can configure PIP and DURATION. PIP positioning option may be selected from „PIP” section in „MAIN” window. There are 8 positions ranging from 0~7. See below for each position. PIP Position location 8) Panic (Force recording) Panic recording will be enabled by selecting „PANIC” from ‘MONITORING” popup.
Image quality and frame rate of Panic record mode is configurable in „SETUP MENU” as shown below. Choose second icon from the left and choose „SETUP”. Upon selecting „SETUP” list option item from second icon in „SETUP MENU” a window will appear with three tabs marked „CHANNEL”, „EVENT” and „PANIC”. Choose „PANIC” tab and you will be able to configure „RESOULTION”, „QUALITY” and „FPS” (Frames per second) for every individual channels.
10) Search The „SEARCH” option is accessible only by ADMIN and MANAGER accounts as default. Regular users may enter search option if given authority by admin. (User authority explained further in Chapter 6.6, item 4). In the „SEARCH” option you may enable „CALANDER SEARCH”, „EVENT SEARCH” and „BOOKMARK SEARCH”. By clicking on „SEARCH” option from „MONITORING” popup it will immediately open the search option window as illustrated below.
5.3.2 PTZ CONTROL Popup Menu The „PTZ CONTROL” popup menu is available after invoking PTZ Control Toolbar and Virtual Joystick. (see page 19 item „3) PTZ CONTROL” ) Press „Menu” button on remote controller or frontal key pad. For the mouse operation right mouse button click to invoke „PTZ CONTOL” popup menu Upon clicking „SELECT CHANNEL” selectable list of all camera labels will appear. Choose the camera label desired to move to the camera for PTZ control.
5.3.3 PLAYBACK Popup Menu While in Playback mode, press „Menu” button on remote controller or frontal key pad. For the mouse operation right mouse button click to invoke „PLAYBACK” popup menu. Upon clicking „GOTO CHANNEL” selectable list of all camera labels will appear. Choose the camera label desired to move to the camera for PLAYBACK control.
5.4 Toolbar 5.4.1 PLAYBACK Toolbar No.
6. DVR Setup 6.1 Operation 6.1.
6.1.
6.1.3 Initialization When powered on, messages displays in order. System will check for connected HDDs. If no HDD is connected, it will move to the next message. To skip checking HDD, click SKIP button or press MENU button. Once initialization is completed, live screen displays.
6.1.4 System Login Window 1) Press right button of mouse or press „MENU” button located on remote controller or frontal keypad, and „MONITORING” popup appears. 2) Click „SETUP MENU”, and Login window pops up. NOTE: If the auto login is enable you may not see the „LOGIN” screen when entering into „SETUP MENU” option. 3) Click User and you can select user grade from the scroll box.
6.2 Display 6.2.1 DISPLAY List Option Item In the „DISPLAY” option on „MAIN SETUP” screen you will see window with 4 tabs „OSD”, „MAIN”, „SPOT” and „VGA”. 1) OSD Tab Window OSD tab in „DISPLAY” window allows you to select what information will be displayed in Live and Playback screen. • DATE/TIME: Check checkbox to display Date/Time on Live screen. • PERCENTAGE BAR: Check checkbox to display recorded percentage on HDD on Live screen. • CAMERA TITLE: Check checkbox to display Camera Title on live screen.
2) MAIN Tab Window To enable sequencing of camera the „EVENT POPUP” should be at „OFF” setting. The „EVENT POPUP” will enable the event triggered camera to display on single channel view on the live view. • SEQUENCE MODE: Define layout to sequence between Full 1ch and 4ch split. • SEQUENCE INTERVAL: Set sequence interval to 1, 2, 3, 4, 5, 10, 15, 20, 30 seconds. • EVENT POPUP: Select „ON” or „OFF” to enable popup screen for event trigger.
Check checkbox of camera channel to activate Spot output. 4) VGA Tab Window In VGA Tab window is the location for configuring VGA type monitor. DVR must have VGA Card pre installed (Optional purchase item) to connect DVR to TFT LCD or CRT monitors.
6.2.2 CAMERA List Option Item The „CAMERA” list option item is selectable from „DISPLAY” group icon. By selecting „CAMERA” list option item, window with two tabs appears. („CAMERA” tab and „PTZ” tab.) 1) CAMERA Tab Window In „CAMERA” tab window you can set the title and adjust the color, hue, and contrast of each camera. • NO.: Click the „NO. (Number)” button to show the „COPY SETTINGS” popup menu.
2) PTZ Tab Window Configuration for PTZ camera is performed in „PTZ” tab window • PROTOCOL: Click Protocol column and select PTZ camera protocol type from the list. • PTZ ID: Assign device IDs to each camera from 0 to 255. • SPEED: Set PTZ control speed from 1 to 7 level. • BAUDRATE: Set RS-485 communication speed. Set communication speed among 9600, 19200, 38400, 57600 and 115200.
6.2.3 REMOTE CONTROL list option item The „REMOTE CONTROL” list option item is selectable from „DISPLAY” group icon. By selecting „REMOTE CONTROL” list option item, window with two tabs appears. („RS232” tab and „REMOTE CONTROL” tab) 1) RS232 Tab Window Configuration for RS-232 is performed in „RS232” tab window • BAUDRATE: Set value among 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200.
6.3 Record 6.3.1 Setup These are three profiles that BCR series support: Channel: Set recording for Continuous recording Event: Set recording for Alarm and Motion detection. Panic: Set recording for panic recording The record will perform on a profile basis Recording Priority (PANIC > EVENT > CHANNEL) 1) Channel Set recording quality of each channel in continuous mode only Applicable schedule: Time, Time+Motion, and Time+Alarm • No.: Click to popup Copy Setting box.
2) Event Set recording quality of each channel when event occurs.
4) Record Profile Example NOTE: PLEASE READ BELOW CAREFULLY FOR PROPER RECORD SETUP. Recording setup (resolution, quality, and fps of each camera) must be selected properly in order to record in every occasion. Channel Profile Event Profile CH1 Setting: Time-lapse record only. No record when event occurs in CH2 as ‘No Record’ is selected in Event Resolution (Time Mode in Schedule Setup) CH2 Setting: Event record only. No record during time-lapse.
• When PANIC mode is triggered, all resolution-selected channels (cameras) will activate and start to record regardless modes in schedule. • PANIC recording can be started in both Live OSD and Front Key. 6.3.2 SCHEDULE List Option Item By clicking the „SCHEDULE” list option item in „RECORD” setup group icon the „SCHEDULE” tab window will appear.
6.3.3 BACKUP List Option Item The „BACKUP” list option item is selectable from „RECORD” group icon. By selecting „BACKUP” list option item, window with „CDRW BACKUP” tab and „USB BACKUP” tab appears.
2) USB BACKUP Tab Window Recorded Video Information • FROM: Start time of recorded data on HDD • TO: End time of recorded data on HDD Backup Information • MEDIA: Available storage size of the inserted solid state media (USB memory stick only) • FROM: Start time of recorded video data to backup on USB memory media device • TO: End time of recorded video data to backup on USB memory media device • BACKUP SIZE: Total size of data to be backed up ranging from 1MB to space available on inserted USB memory media
6.4 Event 6.4.1 ALARM List Option Item The „ALARM” list option item is selectable from „EVENT” group icon. By selecting „ALARM” list option item, „ALARM-IN” tab window appears. 1) ALARM-IN Tab Window Set sensor On / Off and Dwell time for each channel in case external sensor activates. • NO.: Click the „NO. (Number)” button to show the „COPY SETTINGS” popup menu. (There are alarm channels 1~4 shown by default). • TYPE: Set external sensor input NO/NC/OFF for each camera.
6.4.2 Motion List Option Item The „MOTION” list option item is selectable from „EVENT” group icon. By selecting „MOTION” list option item, window with „SETUP” tab and „ACTION” tab appears. 1) SETUP Tab Window Set Motion Detection setting for each channel • NO. : Click the „NO. (Number)” button to show the „COPY SETTINGS” popup menu. (There are alarm channels 1~4 shown by default). • TYPE: Set motion mask setting „ON” or „OFF” for each channel.
NOTE: Default Setting of DVR is ‘CLEAR ALL’ which means deactivate all. User must select mask zone firstly, before set ‘Motion’ scheduled Recording. 2) ACTION Tab Window Set Alarm-Out On / Off for each channel in case motion is detected. NO.: Click the „NO. (Number)” button to show the „COPY SETTINGS” popup menu.
6.4.4 ALARM-OUT List Option Item The „ALARM-OUT” list option item is selectable from „EVENT” group icon. By selecting „ALARM-OUT” list option item, window with „SETTING” tab and „SCHEDULE” tab appears. 1) SETTING Tab Window • DURATION: Output dwell time for Alarm-Out when trigger by Alarm/Motion/Video-Loss events configurable between 1 to 99 seconds. 2) SCHEDULE Tab Window • DAY: Select day of a week for output selectable by ALL, MONDAY ~ SUNDAY, WEEKDAY and WEEKEND.
6.4.5 BUZZER List Option Item The „BUZZER” list option item is selectable from „EVENT” group icon. By selecting „BUZZER” list option item, window with „BUZZER” tab appears. In this window configuration of Buzzer to be on or off is set. • KEY BEEP: Set „ON” or „OFF” to enable and disable audible beep for mouse, frontal key pad or remote controller entry. • VIDEO LOSS: Set „ON” or „OFF” to enable and disable audible beep for Camera Loss.
• IP ADDRESS popup: In case of Static IP, Type IP address in IP ADRESS window. • PORT: Port setup is configurable between 10 to 65000. 50000 is default port for the DVR. Some networks may require router or firewall configuration to enable in-coming and out-going ports to be opened. Consult your network administrator to open assigned port for the DVR. • WEBSERVER: Select the checkbox ON or OFF to enable and disable Web Server option.
3) TRANSMISSION Tab Window Image of selected channel will be transmitted to Viewer of IRS. Default setting: all channels selected 6.5.2 NOTIFICATION List Option Item The „NOTIFICATION” list option item is selectable from „NETWORK” group icon. By selecting „NOTIFICATION” list option item, window with „SETTING” tab, „EMAIL” tab and „EVENT” tab appears. 1) SETTING Tab Window Set notification for both e-mail and event server.
2) EMAIL Tab Window • SEND E-MAIL ON/OFF: Select ON to enable, OFF to disable • SEND SEVER IP: Enter the SMTP (out going mail) server IP. • SEND PORT: Enter the SMTP (out going mail) server port number obtained from your ISP. (in many cases your Internet Service Provider may have special setting requirements or restriction for SMTP settings. You may have to obtain an email account service that provides SMTP relay service that lets you bypass the ISP restrictions.
6.6 System The „INFORMATION” list option item is selectable from „SYSTEM” group icon. By selecting „INFORMATION” list option item, window with „INFORMATION” tab appears. 6.6.1 INFORMATION List Option Item • LANGUAGE: Set language of System Menu between English, French, Spanish, Italian, Portuguese, Dutch, Russian, German, Turkish and Polish. • VERSION: Displays current firmware version for the DVR. • UPGRADE SW: Button used to upgrade current firmware.
Click Upgrade SW button, and pop-up box appears. • Storage Status: Shows firmware update progress. • Upgrade File: Name of file to upgrade • Information: Shows error code in case of error Recording will stop while upgrading. Click IMPORT SETUP button, and import window pops up.
6.6.2 DATE/TIME List Option Item The „DATE/TIME” list option item is selectable from „SYSTEM” group icon. By selecting „DATE/TIME” list option item, window with „DATE/TIME” tab, „HOLIDAY” tab and „TIME SYNC” tab appears. 1) DATE/TIME Tab Window Set Date/Time of the DVR unit. • DATE: Set Year, Month, Day. Year can be set from 2008 to 2099. • TIME: Set Hour, Minute, Second • DATE FORMAT: Choose date format among YY/MM/DD, MM/DD/YY and DD/MM/YY.
2) HOLIDAY Tab Window Set national holidays or holidays on calendar to record as setting for Sunday in Schedule Record Setup. The „HOLIDAY” setting allows the option to preset all Holidays on the DVR calendar. You can then specify to record with the „HOLIDAY” settings on the „SELECT DAY OF WEEK” in the „SCHEDULE RECORD” setup. • ADD: Click the „ADD” button and today’s month and day will be added on the screen. Click month and day to change the date of the holiday.
to the DVR due to unforeseen restriction with SNTP provider. If this event happens please obtain a different SNTP server IP address and retry. • RETRY COUNT: Select from 1 to 30 retries • INTERVAL: Automatic Sync Interval (0.5, 1, 2, 3, 4, 5, 6, 12, 24 hours) • LAST SYNC TIME: Shows time of Last Sync. 6.6.3 STORAGE List Option Item The „STORAGE” list option item is selectable from „SYSTEM” group icon. By selecting „STORAGE” list option item, window with „INFORMATION” tab appears.
6.6.4 USER List Option Item The „USER” list option item is selectable from „SYSTEM” group icon. By selecting „USER” list option item, window with „USER” tab appears. Set password for each user grade or check Auto Login checkbox for auto Login. • USER: Choose between admin, manager, user 1 ~ user 8. • PASSWORD: Set password for each user grade. (Maximum 8 characters. Upon selecting „EDIT” button it invokes „CHANGE PASSWORD” popup window.
If you click „EDIT” in „AUTHORITY” section and AUTHORITY SETUP window pops up. Set authority to access for each user type using this method. Administrator account has all the menu item enabled and it is only required Corresponding user type will have authority to access certain menu item and those access items are shown with check box enabled. Only Admin has authority to enable checkbox. 6.6.5 LOGOUT List Option Item The „LOGOUT” list option item is selectable from „SYSTEM” group icon.
7. DVR Operation 7.1 Live Monitoring Once DVR completes its initialization, live screen displays on connected monitor with live audio through connected speaker. Default mode is displaying all connected camera channels at once. Pressing a certain camera channel button will switch display to full screen mode of the camera channel. This mode continues unless other mode is selected. Press MODE button on frontal key pad or remote controller to switch to other display formats.
7.1.4 SEQ While in full screen mode, press SEQ button on frontal key pad or the remote controller to cause channel of connected cameras to display sequentially according to the preset dwell time. Access MENU - Display - Display - Main - Sequence Interval Popup for dwell time setup. (illustration available in page 33) Access MENU - Display - Display - Main - Sequence Mode Popup for channel display mode.
For PAN left and right, press LEFT and RIGHT buttons, and for TILT up and down, press UP and DOWN buttons. For ZOOM IN, press Wide button, and for ZOOM OUT, press Tele button. For focusing, press NEAR or FAR buttons.
Please refer to the user’s manual provided by PTZ camera manufacturer for proper settings. Some functions may not be supported, depending on the detailed specification of camera. Popup-Menü zur PTZ-Steuerung Easy PTZ control with mouse operation: With virtual joystick, user can control PAN left/right, TILT up, down with mouse operation. No.
7.2 Event Monitoring Event Monitoring Setup (1) For event monitoring, user must have authority for Schedule and Event. (Access Menu - System - User - Authority and check Schedule and Event. Illustrated on page 58) (2) Access Menu - Record - Schedule to set Recording type for Alarm-In or Motion.
7.3 Mouse Operation For easy operation while live monitoring, user can use mouse (PS2) instead of key buttons. In split screen mode, double clicking a certain channel screen will switch the channel into a full screen mode. Double clicking the screen again will return to previous split display mode.
7.4 Record Record Setup (refer to Chapter 6.3 for record setup details) (1) For Record, user must have authority for Record. (Access Menu - System - User - Authority and check Record, (illustrated on page 58) (2) For Continuous record: Access Menu - Record - Setup - Channel - Resolution and set record quality settings. For event record: Access Menu - Record - Setup - Event - Resolution and set record quality settings.
7.5.1 Calendar search Recorded data displays in calendar Search. • << Shows previous month • >> Shows next month • Goto: Date, Time • Goto 1st box: Shows date in YY-MM-DD format to search. • Goto 2nd box: Shows Hour to search. Change Hour from 0~23 by clicking the box. • Goto 3rd box: Shows Minute to search. Change Minute from 0~59 by clicking the box. • Goto 4th box: Shows Second to search. Change Second from 0~59 by clicking the box.
Yellow cubic contain recorded data of alarm + motion recording Cyon cubic contain recorded data of alarm + time recording Small Dots doesn’t contain recorded data. 1 dot/cubic is 1 minute. 7.5.2 Event search Recorded data for Event (Motion, Alarm, Loss, Panic) displays in Event Search.
Click ALL TYPE button and you can choose a event type to be listed from scroll box. Click CHANNEL button and you can choose a channel to be listed from the scroll box. 7.5.3 Bookmark search The Bookmark search screen displays a list of the video associated with bookmark in the playback mode.
7.6 Playback User who has authority to playback can play recorded data. Set authority from Menu - System - User - Authority. (illustrated on page 58) While in Live mode, user can playback from Monitoring popup menu, or by clicking Playback button from Search menu.
7.7 Network Setup 7.7.1 DVR Network Setup Verifying Network Settings in a Windows 98/2000/XP/Vista Environment. 1) Click Windows START button. 2) Click RUN and input „cmd”. (In Windows Vista, you may have to enable the run command box) 3) Input „ipconfig” from COMMAND PROMPT. (In Windows Vista, you have to run this command under Administration Mode) 4) Check IP address, Subnet Mask and Gateway. 5) Type „Ping xxx.xxx.xxx.xxx” (IP address).
7.7.2 Static IP Input the IP address assigned from your Internet Service Provider in IP SETUP. 1) Verify if the IP address is OK with your PC before connecting DVR.
3) Access Menu - Network - LAN - Ethernet in DVR. 4) Set IP TYPE to STATIC. 5) IP address popup button In case of router connection Assign an internal IP address to the DVR. (Ex: 192.168.0.105, The IP scheme must match your router’s settings) The Assigned IP address should only be used for the DVR internally (On the same LAN). In case of direct connection Assign the static IP address to DVR. (Ex: 211.106.1.
12) Click IRS Setup and click Add button. 13) Address / Port / User ID / Password Box: In case of Router connection Internal connection • Address: Input assigned IP address to DVR. (Access Menu - Network - LAN - Ethernet to see assigned IP address) • Port: Input Port number. 50000 recommended. (Input same Port number on Router and DVR in this box.) • User ID: Input same ID as in DVR. • Password: Input same Password as in DVR.
7.7.3 Dynamic IP Select DYNAMIC IP from DVR’s TCP/IP SETUP and IP address will be assigned from ISP’s DHCP server. 1) Verify if IP address is OK with your PC before connecting DVR. 2) Connect dynamic IP LAN cable to DVR after verification.
3) Turn off the Modem provided by the ISP, and turn on again. (This process is to reset client’s MAC from ISP. Wait for 30 seconds after turning on.) 4) After the modem is completely powered on (check LED indicators on the modem to verify), turn the DVR off and turn on again. 5) Access Menu - Network - LAN - Ethernet in DVR. 6) Set IP TYPE to Dynamic and click DHCP button, and IP address and Gateway will be read automatically. 7) Set IP Port.
10) Click IRS Setup and click Add button. 11) Address / Port / User ID / Password Box: In case of Router connection Internal connection • Address: Input assigned IP address to DVR. (Access Menu - Network - LAN - Ethernet to see assigned IP address) • Port: Input Port number. 50000 recommended. (Input same Port number on Router and DVR in this box.) • User ID: Input same ID as in DVR. • Password: Input same Password as in DVR.
7.7.4 E-Mail setup 1) Send Server IP address setup In Send Server IP box, input SMTP server IP address received from System Manager. In case users don’t know SMTP server IP address, ask to server administrator. Check send server IP for Outlook Express: Open Outlook Express, and click TOOLS(T) – ACCOUNT(A). Click PROPERTY(P), and property window pops up as left image.
Click SERVERS tap, and you can check SMTP address. Click Windows START button, and click RUN and input „cmd”. Input „ping xxxxx.xxx(SMTP address)” and you can check IP address. Set this IP address in Send Server IP popup button.
2) Send Port Setup Input 25 for mail port number in DVR. (some SNTP server might have different send port address consult with your network administrator or email provider). 3) Send Server ID / Send Server PW Setup Input ACCOUNT NAME(C) to Send Server ID on your DVR. Input PASSWORD(P) to Send Server PW on your DVR. In case users don’t know Send server ID/PW, ask to SNTP server administrator. 4) Recipient Setup Input E-MAIL ADDRESS(M) to Recipient on your DVR.
Received e-mail example: shown in detail below 8. Integrated Remote Station 8.1. IRS Setup 1) See minimum and recommended system requirement below. Contents Min. Spec. Recommended Spec. Intel Pentium 4 Core2Duo 1.8 or higher CPU Intel Pentium 4 3.0GHZ Main memory 512MB 1GB or higher Video memory 128MB 512MB or higher HDD 80GB 120GB or higher Network Cable/DSL Fast Ethernet OS Window XP, Window Vista Monitor 1024 x 768 (with 24 bit color) or higher Others Direct X 9.
2) Insert software CD and run install file. Click Next button to continue. 3) S-IRS program will install itself in C:\Program Files\S-IRS folder unless specified differently by user. If you want to change directory, click Change button. Click Next button to continue. 4) If you want to review or change any of installation settings, click BACK, but if you want to proceed, click NEXT.
8.2 IRS Operation 8.2.1 IRS (Integrated Remote Station) Display Integrated Application call buttons IRS is suite of application software that has following applications mentioned below. These applications are called up by clicking on the buttons seen below the main IRS screen.
8.2.2 Client Setup CLIENT SETUP: Setup a list of DVRs within the S-IRS application • ADDRESS: Input same IP address set on DVR • PORT: Input same Port number set on DVR • USER ID: Input same ID as in DVR • Password: Input same Password as in DVR NOTE: You must configure below settings before proceeding. • IP address and Port number: [Menu]-[Network]-[LAN]-[Ethernet] • User ID and Password: [Menu]-[System]-[User] • Select User ID among Admin, Manager, User 1 ~8 • Admin has authority to access all menus.
8.2.3 Remote Setup REMOTE SETUP: Change DVR setup remotely over network. • MANUAL: Select to input IP address and Port number manually. • ADDRESS: Locate DVR’s IP address then enter it in this field box. • PORT NUMBER: Locate DVR’s TCP port setting then enter it in this field box. • ID: Locate ID assigned to the DVR then enter it in this field box. • PASSWORD: Locate password assigned to the DVR then enter it in this field box. • CONNECT: Connect to access DVR’s SETUP MENU.
8.3 Remote Viewer 1) DVR connection setup: Input IP address, Port number, ID, Password 2) System Information: Displays DVR connection and progress status. 3) PTZ Control: Control PTZ cameras connected to DVR (PTZ setting in DVR must be completed to enable operation of PTZ.) 4) Connect: Connect to DVR via network to view live image. Disconnect: Disconnect network connection 5) Setup: Set quality and frame rate for each camera channel.
8.4 Search 8.4.1 Search 1) DVR connection setup: Input IP address, Port number, ID, Password. 2) System information: Displays connection status and system operation information. 3) Start / End: Displays start time and end time of total recorded data. 4) Connect: Connect to DVR via network. Disconnect: Disconnect network. 5) Event: Click to pop up window for search by date, event and bookmark. 6) Edit: Edit freeze image in full screen mode.
8.4.2 Percent / Date search Click EVENT button from main Search page. 1) Start / End: Displays start time and end time of total recorded data on DVR 2) Date / Time: Search by input date and time 3) Search bar: Search by percentage of recorded data on HDD 4) OK: Request DVR to search data on set time From main Search page, click PLAY button to begin playback on set time. 5) Cancel: Close search window 8.4.3 Event list search Click date on calendar, and Event List of the day will be displayed.
8.4.4 Bookmark list search Every time the user, logged in as Admin or Manager, pressed the BOOKMARK button, new time data is created on the list. Select time data and click OK to playback, or just double click the time data. 8.5 Backup 1) To run BACKUP, input IP Address and Port, and click Connect Test button.
2) Click Connect Test button, and when network connection is successful, „Success Connect Test!„ message will appear in the message box. 3) Click Lock button, and receives information of recorded start time / end time from DVR. It will automatically update information every 10 seconds, or click Update button for immediate update.
4) Click Set Backup Time button and set Start Time, End Time, Save File Path, File Size, and click Apply button. • Recorded Start Time: Start time of recorded data on HDD at the time of clicking LOCK button. • Recorded End Time: End time of recorded data on HDD at the time of clicking LOCK button. • Save File Path: Configuring path for local PC that will retain the recorded information. • Maximum Save File Size: Split file size into 10MB, 50MB, 100MB,150MB, 200MB~700MB.
8.6 Player 8.6.
8.6.2 Player – Edit Panel IMAGE EDIT 1) CONTRAST: Set contrast in full screen mode 4) IMAGE SAVE: Save full screen freeze image to file : Used to increase the contrast of images : Save still picture in JPEG file format Image will be saved in the folder where playback program is installed.
9. Frequently Asked Questions (FAQ) Q. DVR will not turn on even if the power switch is „ON” position. A. Make sure the DVR is connected to the DC 12V power jack. Q. After turning on the DVR, Power LED on front panel lights, but no video output on monitor. A. Make sure the monitor is turned on and connected to DVR. Check monitor’s brightness control. Check if the video output cable on the DVR is well connected to the video input cable on the monitor. Q. Remote controller doesn’t work. A.
10. Technical Specifications Type Art. No. Series Operation mode Video standard Video inputs (amount) Video inputs Main exits Video outputs Spot monitor Audio inputs Alarm inputs Activity detection Event recording Alarm recording Alarm out Acoustic alarm display Alarm outputs Max. recording resolution Compression standard Image size Max. recording rate Recording speed Digital storage media Harddisk capacity (internal) Max.
Type Art. No.
Appendix A – Factory Default Value When you press Default All button on Menu - System - Information all values will be defaulted as example-factory setting values. See below for detailed factory default values.
Network Menu MENU SUBMENU MENU TITLE FACTORY DEFAULT VALUE LAN Ethernet MAC Address 00-0A-A2-08-08-68 IP TYPE Dynamic Port 50000 DDNS On/Off Off DDNS Server Static IP DDNS 211.062.253.088 0000 Notification DVR ID SDVR 16CH Update Interval 10 Last Update ----/--/-- --.--.-- Transmission CH1 ~ CH16 Checked Email Send M-mail On/Off Off Retry Count 10 Sender Server IP 210.126.014.160 Send Port 26 Send Server ID SDVT Send Server PW **** Sender hotmail.
Device Menu MENU SUBMENU MENU TITLE FACTORY DEFAULT VALUE Camera Camera Copy Settings CH1: Checked, CH2~CH16: Not checked Title CAM01 ~ CAM16 Covert Off Adjustment Brightness –> -10 Contrast –> -5 Saturation –> +16 Hue –> +16 Position -> +7 PTZ Display OSD Copy Settings CH1: Checked, CH2~CH16: Not checked Protocol PELCO-D PTZ ID 1 ~ 16 Speed 7 Baud rate 9600 Date/Time Checked Percent Bar Checked Camera Title Checked Resolution/Quality Checked Alarm/Motion Event Checked
MENU SUBMENU MENU TITLE FACTORY DEFAULT VALUE RS232 RS232 Baud rate 115200 REMOTE CONTROL Buzzer Buzzer Data bits 8 Stop bits 1 Parity None Remote Control Type SINGLE Buzzer On Video Loss On Alarm-In On Motion Detect On Record Menu MENU SUBMENU MENU TITLE FACTORY DEFAULT VALUE Setup Channel Copy Settings CH1: Checked, CH2~CH16: Not checked Resolution CIF Quality High Event Panic Schedule Backup Schedule CDRW Backup USB Backup FRS 12 Overwrite Not checked Cop
Event Menu MENU SUBMENU Alarm Alarm-In Alarm-Out Motion Setup Action Video Loss Video Loss MENU TITLE FACTORY DEFAULT VALUE Copy Settings CH1: Checked, CH2~CH16: Not checked Type N.
Appendix B – Remote Control PTZ On/Off PTZ CONTROL PTZ SET Search Menu SEARCH SET PRESET CLEAR CLEAR PRESET Menu MENU F1 F2 F3 1~9 Select Ch / Input number F4 0 Indicates 2 digits „0” + „0” = „10” „0” + „1” = „11” GOTO GOTO PRESET AUTO AUTO PAN FUNC Press REC button and then press number button for Panic recording.
SLD Security & Communications The Old Forge, Ockham Lane, Ockham, Surrey GU236PH England Phone +44.1483225633 · Fax +44.1483225634 sales@sld.co.uk · www.sld.co.