System information

Enecsys Installation and Operation Manual Version 1.6June 6 2012
38
6.6.2 Disconnecting a micro inverter
CAUTION: micro inverters must be disconnected in the correct sequence, as
shown below: otherwise they may be damaged.
Isolate the AC side of the micro inverter bus cabling from the mains grid using the
isolation switch or circuit breaker, as applicable in the country of installation.
Disconnect the micro inverter’s AC branching cable from the distribution unit and
use an end cap to seal the open connection point on the distribution unit.
Disconnect the DC link cables between the micro inverter and the PV module’s
junction box.
6.7 Micro inverter technical details
Environmental category:
Outdoor use
Pollution degree:
Pollution degree 3
Enclosure rating:
IP66
Operating temperature range:
-40 to +85 degrees C
Relative humidity
4% to 100%
Overvoltage category – input DC side:
Overvoltage II
Overvoltage category – output AC side:
Overvoltage III