System information

Enecsys Installation and Operation Manual Version 1.6June 6 2012
32
6.4 Mounting the duo micro inverter
The duo micro inverter has several mounting points.
The installer must choose the most suitable method of mounting the micro inverter.
The body of the micro inverter must not be in contact with either the roof surface or
the PV module.
There must be at least 10mm clearance between the body of the micro inverter,
the roof surface and the rear of the PV module. Ensure that the bolts used are
well clear of the module backsheet, even under the module’s snow load
conditions.
ATTENTION: The 360-72 micro inverter does not have an omnidirectional
antenna. It must be mounted with the antenna cover facing downwards, towards
the roof surface. If it is mounted the wrong way up, it will not be able to
communicate with the Enecsys gateway.