1.2 Safety
Before installing and using any Enecsys Micro-inverter please ensure that you have fully read and
understand all of the installation instructions and heed all warnings and cautions given.
Warning: The installation and/or replacement of Enecsys Micro-inverters must only be car-
ried out by qualified professionals.
Warning: All electrical installations should be performed in accordance with all local and
national electrical installation codes and practice.
Caution: The Aluminium body of the Enecsys Micro-inverter serves as the heat-sink for the
unit and as such can reach temperatures of 70
C. The Enecsys Micro-inverter should not be
touched whilst in operation.
Warning: Lightning protection
To avoid voltages being induced by lightning, the roof-mounted wiring should be arranged
as radial branches, or as a single branch. Wiring loops or rings should not be used. Further
independent active protection against lightning strike may be required, to local and
national standards.
Warning: Isolation of the AC cabling
The AC wiring from the inverters must have provision for electrical isolation from the grid
mains supply, so that inspection, fault detection, testing, maintenance and repair can be
performed.
Warning: Never disconnect any Photovoltaic module from an Enecsys Micro-inverter with-
out first isolating the AC mains.