of Micro-inverters in direct communication with the Gateway. The number presented on the
screen should match the number of inverters used as part of the installation.
5. Switch the Gateway into installer mode from the ‘home user’ screen by inserting a pointed
object into the installer mode slot for approximately five seconds.
6. Check the strength of the communication link between the Micro-inverters and the Gateway.
One of the following 3 symbols will be displayed:
7. Having established that the communication link between the Micro-inverter/s and the Gate-
way is sufficient, proceed to the 'commissioning phase' of the installation process.
8. If an insufficient communication link is presented, a Repeater or Double-Repeater may need
to be installed, proceed to “Repeater and Double Repeater”.
Symbol Description Action
X Very weak communication link Add a Repeater.
? Marginal communication link Add a Repeater.
Good Communication link This symbol displayed to assure a reliable communication.
Table 1: Gateway status icons.