Chapter 8 Troubleshooting
Contact the system installer or Enecsys support for assistance if you cannot understand how
to solve the problem.
8.1. Inverter LED Functions
The inverter body has an LED on its exterior. If the LED shows green, it indicates proper func-
tion. A red LED indicates a fault condition.
Figure 26. Inverter LED in fault condition
LED action Description
Red - no blinking No DC link or GFDI.
Red - single blink DC Link OK, grid voltage out-of-bounds
Red - two blinks with pause in between DC Link OK, grid frequency out-of-bounds
Red - three blinks with pause in between DC Link OK, no power-good signal
8.2. Communication
Problem Solution
No illuminated display presented when the Enecsys
gateway is powered on.
Replace the Enecsys gateway.
The Enecsys gateway does not connect to the inter-
net.
Check the Ethernet cable and router. Replace the
Enecsys gateway.
The Enecsys gateway shows 0 when the micro invert-
ers are installed.
Verify that the micro inverters been installed correctly.
Verify the AC connections have been made: the con-
nectors should snap lock together during connection.
Verify that no cabling has become pinched by the PV
modules.
If the installation is on a metal roof or on a roof with a
metal liner, has a repeater been installed?
The Enecsys gateway is not showing the correct num-
ber of installed micro inverters.
Check PV module / micro inverter connections.
Is there
sunlight on the modules? (During
the night the gateway will always show 0 unless a re-
peater or double repeater has been installed, in which
case the gateway will show 1 or as many repeaters as
there are in the installation).