a) Strip cable jacket
18-25 mm
b) Separate the seal/clamp ring and sealing nut,
then insert the stripped cable end through
them in the order shown.
c) Insert the wire ends
into the receptacles.
d) Push the cable to the end.
Gently test the cable to see if
it is secured.
e) Screw the sealing nut into the body.
Recommended torque = 25Kgf-cm
Body
Seal/clamp ring
Sealing nut
Figure 23. T-cable end cap installation
T-Cabling System: connections to the AC branch system
Connect the unterminated end of the
T-cable to the AC Mains.
WARNING
Connection of the AC cable to the mains
electrician.
!
ATTENTION:
Disconnecting a drop cable connection from the inverter AC connector requires the Mi-
cro Inverter AC disconnect tool. It is the same tool that is used to remove the protective
caps from the drop cable connectors.
6.3.2. Cable Joiner
The cable joiner can be used to connect sections of trunk cabling.
When used as directed, the cable join will be able to withstand outdoor conditions.
Once the housing is joined, separating the halves requires its own disconnection tool.
!
ATTENTION
Make sure each
individual conductor
into one receptacle.
1
2
3
4
5
6
7
8
9