User's Manual

Table Of Contents
Micropilot NMR84
Endress+Hauser 35
Application packages
Advanced tank measurement
methods
The device software provides the following tank measurement methods:
Direct level measurement →  35
Hybrid tank measurement system (HTMS) →  36
Hydrostatic tank shell correction (HyTD) →  37
Thermal tank shell correction (CTSh) →  37
Direct level measurement
If no advanced tank measurement methods have been selected, level and temperature are measured
directly.
Direct level measurement modes
Measuring mode Installation example Measured variables Calculated variables
Level only
1
2
A0027111
1 Micropilot
2 To inventory management system
Level None
Level + temperature
3 1
2
A0027112
1 Micropilot
2 To inventory management system
3 Temperature transmitter (point or average)
Level
Temperature (point or average)
None