User's Manual

Table Of Contents
DRAFT
Micropilot FMR53, FMR54
88 V. 1, Rev. 7, 26-10-2012 Endress+Hauser
Feature 010 Approval Available for Safety Instructions HART Safety Instructions
PROFIBUS
FOUNDATION Fieldbus
B3 ATEX: II 1/2 G Ex d [ia] IIC T6-T1 Ga/Gb
ATEX: II 1/2 D Ex ta IIIC Txx°C Da/Db
FMR53
FMR54
XA00684F XA00692F
B4 ATEX:II 1/2 G Ex ia IIC T6-T1 Ga/Gb
ATEX: II 1/2 G Ex d [ia] IIC T6-T1 Ga/Gb
FMR53
FMR54
XA00681F XA00689F
IA IECEx: Ex ia IIC T6-T1 Ga FMR53
FMR54
XA00677F XA00685F
IB IECEx: Ex ia IIC T6-T1 Ga/Gb FMR53
FMR54
XA00677F XA00685F
IC IECEx: Ex d [ia] IIC T6-T1 Ga/Gb FMR53
FMR54
XA00680F XA00688F
ID IECEx: Ex ic [ia Ga] IIC T6-T1 Ga/Gb/Gc FMR53
FMR54
XA00678F XA00686F
IE IECEx: Ex ta IIIC T
500
xx°C Da FMR54 XA00682F XA00690F
IF IECEx: Ex ta IIIC Txx°C Da/Db FMR54 XA00682F XA00690F
IG IECEx: Ex nA IIC T6-T1 Gc FMR53
FMR54
XA00679F XA00687F
IH IECEx: Ex ic IIC T6-T1 Gc FMR53
FMR54
XA00679F XA00687F
IL IECEx: Ex nA [ia Ga] IIC T6-T1 Ga/Gb/Gc FMR53
FMR54
XA00678F XA00686F
I2 IECEx: Ex ia IIC T6-T1 Ga/Gb
IECEx: Ex ia IIIC Txx°C Da/Db
FMR53
FMR54
XA00683F XA00691F
I3 IECEx: Ex d [ia] IIC T6-T1 Ga/Gb
IEXEx: Ex ta IIIC Txx°C Da/Db
FMR53
FMR54
XA00684F XA00692F
I4 IECEx: Ex ia IIC T6-T1 Ga/Gb
IECEx: Ex d [ia] IIC T6-T1 Ga/Gb
FMR53
FMR54
XA00681F XA00689F
For certified devices the relevant Safety Instructions (XA) are indicated on the nameplate.
If the device is prepared for the remote display FHX50 (product structure: feature 030: Display, Operation",
option L or M), the Ex marking of some certificates changes according to the following table
8)
:
Feature 010 ("Approval")
Feature 030 ("Display, Operation") Ex marking
BG L oder M ATEX II 3G Ex nA [ia Ga] IIC T6 Gc
BH L oder M ATEX II 3G Ex ic [ia Ga] IIC T6 Gc
B3 L oder M ATEX II 1/2G Ex d [ia] IIC T6 Ga/Gb,
ATEX II 1/2D Ex ta [ia Db] IIIC Txx°C Da/Db
IG L oder M IECEx Ex nA [ia Ga] IIC T6 Gc
IH L oder M IECEx Ex ic [ia Ga] IIC T6 Gc
I3 L oder M IECEx Ex d [ia] IIC T6 Ga/Gb,
IECEx Ex ta [ia Db] IIIC Txx°C Da/Db
Registered trademarks
HART
Ò
Registered trademark of the HART Communication Foundation, Austin, USA
8) The marking of certificates not mentioned in this table are not affected by the FHX50.