User's Manual

Table Of Contents
DRAFT
Micropilot FMR53, FMR54
Endress+Hauser V. 1, Rev. 7, 26-10-2012 45
Installation in bypass
1
2
2
90°
90°
A0019446
å 15
Installation in bypass
1
Marking for antenna alignment
2 Tank connectors
Alighn the marker perpendicular (90°) to the tank connectors.
Measurements can be performed through an open full bore ball valve without any problems.
After mounting, the housing can be turned 350° in order to simplify access to the display and the terminal
compartment.