iTEMP TMT72 Operating menu and parameter description
Endress+Hauser 91
Options No fix
GPS or Standard Positioning Service (SPS) fix
Differential PGS fix
Precise positioning service (PPS)
Real Time Kinetic (RTK) fixed solution
Real Time Kinetic (RTK) float solution
Estimated dead reckoning
Manual input mode
Simulation mode
Factory setting Manual input mode
Location description
Navigation System → Information → Device location → Location description
Description Use this function to enter a description of the location so that the device can be located in
the plant.
User entry Up to 32 alphanumeric characters (letters, numbers and special characters)
Factory setting 32 x '?'
Process unit tag
Navigation System → Information → Device location → Process unit tag
Description Use this function to enter the process unit in which the device is installed.
User entry Up to 32 alphanumeric characters (letters, numbers and special characters)
Factory setting 32 x '?'
HART info submenu
Device type
Navigation System → Information → HART info → Device type
Description Displays the device type with which the device is registered with the HART FieldComm
Group. The device type is specified by the manufacturer. It is needed to assign the
appropriate device description file (DD) to the device.
User interface 4-digit hexadecimal number
Factory setting 0x11D0