iTEMP TMT72 Operation options
Endress+Hauser 23
Submenus
Menu Typical tasks Content/meaning
"Diagnostics" Troubleshooting:
• Diagnosing and eliminating process errors.
• Error diagnostics in difficult cases.
• Interpretation of device error messages and
correcting associated errors.
Contains all parameters for detecting and analyzing errors:
• Diagnostic list
Contains up to 3 error messages currently pending
• Event logbook
Contains the last 10 error messages (no longer pending)
• "Simulation" submenu
Used to simulate measured values, output values or diagnostic
messages
• "Diagnostic settings" submenu
Contains all the parameters for configuring error events
• "Min/max values" submenu
Contains the minimum/maximum indicator and the reset option
"Application" Commissioning:
• Configuration of the measurement.
• Configuration of data processing (scaling,
linearization, etc.).
• Configuration of the analog measured value output.
Tasks during operation:
Reading measured values.
Contains all parameters for commissioning:
• "Measured values" submenu
Contains all the current measured values
• "Sensor" submenu
Contains all the parameters for configuring the measurement
• "Output" submenu
Contains all the parameters for configuring the analog current output
• "HART configuration" submenu
Contains the settings and the most important parameters for HART
communication
"System" Tasks that require detailed knowledge of the system
administration of the device:
• Optimum adaptation of the measurement for
system integration.
• Detailed configuration of the communication
interface.
• User and access administration, password control
• Information concerning device identification HART
information, and display configuration
Contains all the higher-level device parameters that are assigned for
system, device and user management, including Bluetooth
configuration.
• "Device management" submenu
Contains parameters for general device management
• "Bluetooth configuration" submenu (option)
Contains the function for enabling/disabling the Bluetooth interface
• "Device and user management" submenus
Parameters for access authorization, password assignment, etc.
• "Information" submenu
Contains all the parameters for the unique identification of the device
• "Display" submenu
Configuration of the display
6.3 Access to the operating menu via the operating tool
6.3.1 DeviceCare
Function scope
DeviceCare is a free configuration tool for Endress+Hauser devices. It supports devices with
the following protocols, provided a suitable device driver (DTM) is installed: HART,
PROFIBUS, FOUNDATION Fieldbus, Ethernet/IP, Modbus, CDI, ISS, IPC and PCP. The tool is
aimed at customers without a digital network in plants and workshops and Endress
+Hauser service technicians. The devices can be connected directly via a modem (point-to-
point) or a bus system. DeviceCare is fast, easy and intuitive to use. It can run on a PC,
laptop or tablet with a Windows operating system.
Source for device description files
See information → 28