Product Info
Table Of Contents
iTEMP TMT142
2 Endress+Hauser
Function and system design
Measuring principle
Electronic recording, conversion and display of various input signals in industrial temperature
measurement.
Measuring system
1 2
+
-
1 x RTD/TC
1 x RTD/TC
200
200
A0041387
1 Application examples
1 An RTD or thermocouple sensor with field transmitter in remote installation
2 Field transmitter with direct sensor installation - 1 x RTD/TC wired directly
Endress+Hauser offers a comprehensive range of industrial thermometers with resistance sensors or
thermocouples.
When combined with the temperature transmitter, these components form a complete measuring
point for a wide range of applications in the industrial sector.
The temperature transmitter is a 2-wire device with one measuring input and one analog output.
The device not only transmits converted signals from resistance thermometers and thermocouples, it
also transmits resistance and voltage signals using HART
®
communication and as a 4 to 20 mA
current signal. It can be installed as an intrinsically safe apparatus in hazardous areas.
Intuitive commissioning and operation - wireless access to all device data via Bluetooth using the
SmartBlue app.
TMT142
SmartBlue
App
FieldCare/
DeviceCare
HART® Modem
RN221N
PLC
200
A0041386
2 Equipment architecture