Product Info
Table Of Contents
iTEMP TMT142
18 Endress+Hauser
SmartBlue
App
FieldCare/
DeviceCare
HART® Modem
RN221N
PLC
200
ON
OFF
Bluetooth
1
2 3 4
5
A0041440
9 Operating options of device
1 Hardware settings via DIP switches
2 Device configuration via Bluetooth® wireless technology
3 Configuration software, e.g. FieldCare
4 PLC
5 Power supply unit and active barrier, .e.g. RN221 from Endress+Hauser
Local operation Display elements
°C
°F
%
K
10
0
20
30
40
50
60
70
80
90
100
!
1
2
3
4
5
6
7
A0034101
10 LC display of the field transmitter (backlit, attachable in 90° stages)
1 Bar graph display
2 'Caution' symbol
3 Unit display K, °F, °C or %
4 Measured value display, digit height 20.5 mm
5 Status and information display
6 'Configuration locked' symbol
7 'Communication' symbol
Operating elements
To prevent device manipulation, no operating elements are present directly on the display. Various
operating elements for configuring the device are located on the electronics module, which is located
behind the display.