Micropilot FWR30 Technical data
Endress+Hauser 23
14 Technical data
14.1 Input
14.1.1 Measured variable
Measured process variables
• Level: 0 to 15 m (0 to 49 ft) ±10 mm (0.39 in)
• Ambient temperature: –20 to +60 °C (–4 to +140 °F) with an accuracy of ± 2 °C (4 °F)
• Position: Angle of device to the horizontal
The measurement is perpendicular to the product surface
Range: 0 to 180°
14.1.2 Measuring range
0 to 15 m (0 to 49 ft)
A
A0040731
A Distance to level surface
Level in mm = tank empty - distance to level surface
Level in % = (tank empty - distance to level surface) / tank full ⋅ 100 %
Tank empty = from the measuring device to the bottom
Tank full = from the bottom to the measuring device
14.1.3 Operating frequency
80 GHz
14.1.4 Blocking distance
BD
8°
A0041499