7 Operation options
7.1 Overview of operation options
7.1.1 Operation via activation button on device
The blue activation button is locked while an action is being performed and until the
action has been completed.
Action Procedure LED
Activating the measuring device - measure and
transmit
Press the blue activation button briefly (>2 seconds) until the LED is lit
green
The LED flashes green during transmission
The LED is lit green continuously (for 10 seconds) if transmission is
successful
The LED flashes red or is lit red (for 10 seconds) if transmission fails
Action Procedure LED
Deactivating the measuring
device – measure, transmit and
switch off
Press the blue activation button for longer (>7 seconds) until the LED is lit red
The LED flashes green during transmission
The LED flashes green, yellow and red alternately if transmission is successful.
The measuring device is now deactivated.
The LED flashes red or is lit red (for 10 seconds) if transmission fails.
The LED then flashes green, yellow and red alternately to indicate the deactivation of the
measuring device.
The measuring device can also be deactivated via the Value App
In order to activate the measuring device again, the blue activation button must be
pressed again
The blue activation button is locked while an action is being performed and until the
action has been completed
7.1.2 Operation via cloud and app
The measuring device is operated via Netilion Value.
https://netilion.endress.com