Endress+Hauser 11
Blocking distance
BD
A0041499
No signals are analyzed within the blocking distance (BD)
For this reason, the blocking distance can be used to suppress interference signals (e.g.
from condensate) near the antenna
Factory setting: 0 mm
The blocking distance (BD) can be defined in the cloud or set automatically
The setting is made in the blocking distance parameter
The following formula is used for the automatic setting:
Empty tank - full tank - 100 mm (3.94 in) = blocking distance (min. 0 mm)
Installation on ceiling or walls
A
B
A0040688
Installation with "Mounting bracket wall/ceiling".
Individual installation
The measuring device can also be installed without using the two mounting brackets. An
individual bracket can be attached to the underside using the screw thread. The measuring
device can also be attached using commercially available Velcro or adhesive tape. Both
mounting kits available include the same base plate, which makes other custom
installations possible. If the radar antenna is covered by metal objects, the measuring
signal will be distorted.