Specifications
Equipment
LOCATION OF EQUIPMENT
The equipment to filter and heat your Fiberglass Endless Pool
is typically installed at the front of the pool just below the
fiberglass lip (see figure below). The keypad controller for this
system has a 10 foot cord and is usually mounted in the pool
coping. When optional hydrotherapy jets are selected, the jets
are plumbed into the rear wall over the bench and the jet’s
pump is located at the front and plugs into the heater/controller.
The radio controlled 5 horsepower Hydraulic Power Unit is
usually located near your electric service. It requires a single 30
amp, 220 volt, GFCI service. A flexible conduit connects this
power unit to the heater/controller
poolside. Hydraulic lines connect between the front of the pool
and the power unit. Up to 25' of hydraulic line is provided
with the pool. Additional hydraulic line may be ordered when
locating the power unit further away.
For fully in-ground installations where the pool is backfilled and
the equipment is kept at the front, a pit needs to be built at the
front of the pool (see drawing on opposite page). While it is
necessary that all fiberglass pools without our optional bracing
system be backfilled at least 18" from the top of the pool, at the
front, to accommodate equipment, a 24" pit may be formed as
shown. The optional Retractable Security Cover typically covers
this pit and a removable lid should be constructed.
Of course this controller/heater/pump system can also be locat-
ed remotely as can the hydrotherapy jets pump. When the
equipment is positioned remotely, water lines will have to run
back and forth to the pool as will the line for the keypad con-
troller. The high efficiency pump will also be replaced with a
pump designed to be self-priming if the water lines run above
the water level. Consult your design representative if you wish to
remotely locate your water quality equipment.
Equipment
1. Skimmer/Filter (50 Square feet)
2. Shut Off Valve
3. Circulating Pump (120 watts)
4. Heater/Controller
5. Inlet to pool
6. Optional Lights
7. Optional Jets Suction Line
8. Optional Jet Pump
9. Hydraulic Power Unit (HPU)
10. Hydraulic Lines (pressure and return)
11. Flexible Conduit from HPU to Heater/Controller
12. Remote Keypad
13. Optional Retractable Security Cover (opposite page)
1
23
4
5
6
6
7
7
8
11
10
12
9
24"
FRONT ELEVATION
3